Viability and protein secretion from human Hepatoma (HepG2) cells encapsulated in 400‐μm polyacrylate microcapsules by submerged nozzle–liquid jet extrusion
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An interfacial precipitation process to encapsulate mammalian cells in hydroxyethyl methacrylate‐methyl methacrylate (HEMA‐MMA) microcapsules of ∼ 750 in ∼m diameter was previously described. It was not possible to produce smaller capsules due to low shearing force. A new droplet generation scheme was developed by suspending the cell and polymer co‐extrusion nozzle in a uniform co‐axial fluid jet which enabled the production of 300 to 600‐µm diameter capsules. HepG2 hepatoma cells in 400‐µm‐diameter HEMA‐MMA capsules were able to retain their metabolic activity during and after the encapsulation process. The in vitro secretion of plasma proteins α 1‐acid glycoprotein, α 1‐antitrypsin, and fibrinogen by the encapsulated cells was retained. The encapsulated cells secreted less fibrinogen (340 kD) relative to α 1‐acid glycoprotein (42kD), indicating the sieving effect (but not absolute cut‐off) of the HEMA‐MMA membrane. © 1994 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell and environment interactions in tumor microregions: the multicell spheroid model.
Sutherland, R. M. (1988) · Science · doi:10.1126/science.2451290 · Cited by 1,803
Microencapsulated human hepatoma (HepG2) cells: In vitro growth and protein release
Uludag, H., & Sefton, M. V. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271002 · Cited by 74
Self-citation
Cited by
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Technology of mammalian cell encapsulation
Uludag, H., De Vos, P., & Tresco, P. A. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00053-3 · Cited by 601
Self-citationHost response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Polymers in cell encapsulation from an enveloped cell perspective
de Vos, P., Lazarjani, H. A., Poncelet, D., & Faas, M. M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.005 · Cited by 298
“sule, despite application of the same acrylates [311].”
Metadata
- Authors
- Uludag, H., Horvath, V., Black, J. P., & Sefton, M. V.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1994-11-20
- Volume
- 44
- Issue
- 10
- Pages
- 1199-1204
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2018500800
- Cited by
- 44
- References
- 2
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.