CoChat

Monitoring and control of the physiological state of cell cultures

Konstantinov, Konstantin B. · 2000 · Biotechnology and Bioengineering
Cited by 56

The DOI matches its Crossref record.

Abstract

Advances in bioprocess engineering depends ultimately on the level of understanding and control of the physiological state of the cell population. Process efficiency is strongly influenced by changes in the cellular state which should be monitored, interpreted, and, if possible, properly manipulated. In most control systems this function is not explicitly considered, which hampers process development and optimization. Conventional control logic is based on direct mapping of the growth environment into process efficiency, thereby bypassing the cell state as an intermediate control objective. Today, this limitation is well realized, and explicit monitoring and control of cellular physiology are considered to be among the most challenging tasks of modern bioprocess engineering. We present here a generic methodology for the design of systems capable of performing these advanced monitoring and control functions.The term "physiological state" is quantified by a vector composed of several process variables that convey significant information about cellular state. These variables can be selected among different classes, including specific metabolic rates, metabolic rate ratios, degees of limitation, and others. The real-time monitoring of many of these is possible using commercial sensors. The definition and calculation of representative sets of physiological state variables is demonstrated with examples from several fermentor cultures: recombinant Escherichia coli for phenylalanine production, bioluminescent E. coli (harboring lux genes driven by a heat shock protein promoter) for detection of environmental pollutants, plant cell culture of Perilla frutescensfor anthocyanin production, and perfusion cultures of recombinant mammalian cells (NS0 and CHO) for therapeutic protein production.If the physiological state vector is on-line calculated, the fermentation process can be described by its trajectory in a space defined by the vector components. Then, the goal of the control system is to maintain the physiological state of the cell as close as possible to the trajectory, providing maximum efficiency. A control structure meant to perform this function is proposed, along with the mechanism for its design. In contrast to conventional systems which work in a closed loop in respect to the cell environment, this scheme operates in a closed loop in respect to the cell state. The discussed control concept has been successfully applied to the recombinant phenylalanine production, resulting in physiologically consistent operation, total computer control, and high process efficiency. Initial results from the application of the method to perfusion mammalian cell cultures are also presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.260520203

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Konstantinov, K. B.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2000-03-26
Volume
52
Issue
2
Pages
271-289
ISSN
0006-3592 (ISSN-L)
OpenAlex
W2053199660
Cited by
56
References
0
FWCI
1.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.