The development of mammalian cell perfusion cultures is still laborious and complex to perform due to the limited availability of scale‐down models and limited knowledge of time‐ and cost‐effective procedures. The maximum achievable viable cell density (VCD max), minimum cell‐specific perfusion rate (CSPR min), cellular growth characteristics, and resulting bleed rate at steady‐state operation are key variables for the effective development of perfusion cultures. In this study, we developed a stepwise procedure to use shake tubes (ST) in combination with benchtop (BR) bioreactors for the design of a mammalian cell perfusion culture at high productivity (23 pg·cell−1·day−1) and low product loss in the bleed (around 10%) for a given expression system. In a first experiment, we investigated peak VCDs in STs by the daily discontinuous medium exchange of 1 reactor volume (RV) without additional bleeding. Based on this knowledge, we performed steady‐state cultures in the ST system using a working volume of 10 ml. The evaluation of the steady‐state cultures allowed performing a perfusion bioreactor run at 20 × 10 6 cells/ml at a perfusion rate of 1 RV/day. Constant cellular environment and metabolism resulted in stable product quality patterns. This study presents a promising strategy for the effective design and development of perfusion cultures for a given expression system and underlines the potential of the ST system as a valuable scale‐down tool for perfusion cultures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Karst, D. J., Serra, E., Villiger, T. K., Soos, M., & Morbidelli, M. (2016) · Biochemical Engineering Journal · doi:10.1016/j.bej.2016.02.003 · Cited by 151
Self-citationHigh-density mammalian cell cultures in stirred-tank bioreactor without external pH control
Xu, S., & Chen, H. (2016) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2016.06.019 · Cited by 99
Cited by
Tripathi, N. K., & Shrivastava, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00420 · Cited by 575
Perfusion culture of Chinese Hamster Ovary cells for bioprocessing applications
MacDonald, M. A., Nöbel, M., Roche Recinos, D., Martínez, V. S., Schulz, B. L., Howard, C. B., Baker, K., Shave, E., Lee, Y. Y., Marcellin, E., et al. (2022) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2021.1998821 · Cited by 55
Feidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A. (2019) · Processes · doi:10.3390/pr7100683 · Cited by 46
Self-citationSchulze, M., Lemke, J., Pollard, D., Wijffels, R. H., Matuszczyk, J., & Martens, D. E. (2021) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2021.06.011 · Cited by 34
Metadata
- Authors
- Wolf, M. K. F., Müller, A., Souquet, J., Broly, H., & Morbidelli, M.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2019-05-19
- Volume
- 116
- Issue
- 8
- Pages
- 1973-1985
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2942966135
- Cited by
- 39
- References
- 2
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Process design and development of a mammalian cell perfusion culture in shake‐tube and benchtop bioreactors. https://app.cochat.ai/papers/10.1002/bit.26999
- The paper
- Wolf, M. K. F., Müller, A., Souquet, J., Broly, H., & Morbidelli, M. (2019). Process design and development of a mammalian cell perfusion culture in shake‐tube and benchtop bioreactors. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.26999
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.