CoChat

Process‐wide control and automation of an integrated continuous manufacturing platform for antibodies

Feidl, Fabian, Vogg, Sebastian, Wolf, Moritz, Podobnik, Matevz, Ruggeri, Caterina, Ulmer, Nicole, Wälchli, Ruben, Souquet, Jonathan, Broly, Hervé, Butté, Alessandro, Morbidelli, Massimo · 2020 · Biotechnology and Bioengineering
Cited by 99

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Integrated continuous manufacturing is entering the biopharmaceutical industry. The main drivers range from improved economics, manufacturing flexibility, and more consistent product quality. However, studies on fully integrated production platforms have been limited due to the higher degree of system complexity, limited process information, disturbance, and drift sensitivity, as well as difficulties in digital process integration. In this study, we present an automated end‐to‐end integrated process consisting of a perfusion bioreactor, CaptureSMB, virus inactivation (VI), and two polishing steps to produce an antibody from an instable cell line. A supervisory control and data acquisition (SCADA) system was developed, which digitally integrates unit operations and analyzers, collects and centrally stores all process data, and allows process‐wide monitoring and control. The integrated system consisting of bioreactor and capture step was operated initially for 4 days, after which the full end‐to‐end integrated run with no interruption lasted for 10 days. In response to decreasing cell‐specific productivity, the supervisory control adjusted the loading duration of the capture step to obtain high capacity utilization without yield loss and constant antibody quantity for subsequent operations. Moreover, the SCADA system coordinated VI neutralization and discharge to enable constant loading conditions on the polishing unit. Lastly, the polishing was sufficiently robust to cope with significantly increased aggregate levels induced on purpose during virus inactivation. It is demonstrated that despite significant process disturbances and drifts, a robust process design and the supervisory control enabled constant (optimum) process performance and consistent product quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.27296

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 99

Metadata

Authors
Feidl, F., Vogg, S., Wolf, M., Podobnik, M., Ruggeri, C., Ulmer, N., Wälchli, R., Souquet, J., Broly, H., Butté, A., & Morbidelli, M.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2020-02-17
Volume
117
Issue
5
Pages
1367-1380
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W3004744289
Cited by
99
References
6
FWCI
4.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.