Continuous monitoring of IgG using immobilized fluorescent reporters
Abstract
In the manufacture of therapeutic monoclonal antibodies, the clarified cell culture fluid (CCF) is typically loaded onto an initial protein A affinity capture column. Imperfect mass transfer and loading to maximum capacity can risk antibody breakthrough and loss of valuable product, but conservative underloading wastes expensive protein A resin. In addition, the effects of column fouling and ligand degradation require the frequent optimization of immunoglobulin G (IgG) loading to avoid wastage. Continuous real‐time monitoring of IgG flowthrough is of great interest, therefore. We previously developed a fluorescence‐based monitoring technology that allows batch mix‐and‐read mAb detection in the CCF. Here, we report the use of reporters immobilized on cyanogenbromide‐activated Sepharose 4B resin for continuous detection of IgG in column breakthrough. The column effluent is continuously contacted with immobilized fluorescein‐labeled Fc‐binding ligands in a small monitoring column to produce an immediately‐detectable change in fluorescence intensity. The technology allows rapid and reliable monitoring of IgG in a flowing stream of clarified CCF emerging from a protein A column, without prior sample preparation. We observed a significant change in fluorescence intensity at 0.5 g/L human IgG, sufficient to detect a 5% breakthrough of a 10 g/L load, within 18 s at a flow rate of 0.5 ml/min. The current small‐scale technology is suitable for use in process development, but the chemistry should be readily adaptable to larger scale applications using fiber‐optic sensors, and continuous IgG monitoring could be applicable in a variety of upstream and downstream process settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Immobilized fluorescent reporters had been recently employed in the monitoring of the capture step in downstream processing, where column breakthrough of 5% could be detected [93].”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [93]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 26
- 10.1016/S0956‐5663(03)00046‐0 · DOI
- 10.1007/s100470200010 · DOI
- 10.1021/pr300476w · DOI · Paper page
- 10.1038/srep30526 · DOI
- 10.1016/j.procbio.2015.03.005 · DOI
- 10.1016/j.chroma.2017.10.030 · DOI
- 10.1007/s00216‐016‐9824‐1 · DOI · Paper page
- 10.1016/S0021‐9673(99)00539‐7 · DOI
- 10.1016/j.jbiotec.2015.06.393 · DOI
- 10.3390/bioengineering1040188 · DOI
- 10.3390/pr9010172 · DOI · Paper page
- 10.1016/J.COPBIO.2014.06.017 · DOI
- 10.1007/10_2018_59 · DOI
- 10.3390/ijms20071729 · DOI
- 10.1016/0022‐2313(75)90003‐4 · DOI
- 10.1016/j.tibtech.2020.07.004 · DOI
- 10.2174/978160805269111201010081 · DOI
- 10.1016/j.bios.2020.112327 · DOI
- 10.1002/JSSC.201800963 · DOI
- 10.1002/bit.26078 · DOI
- 10.4049/jimmunol.147.6.1877 · DOI
- 10.3390/s141018941 · DOI
- 10.1016/j.ab.2017.07.013 · DOI
- 10.1021/acs.analchem.0c04269 · DOI
- 10.1038/srep13434 · DOI
- 10.1002/BIT.25615 · DOI
Cited by
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45
Metadata
- Authors
- Goyal, A., Vu, B., Maranholkar, V., Patil, U., Kourentzi, K., & Willson, R. C.
- Affiliations
- William A. Brookshire Department of Chemical and Biomolecular Engineering University of Houston Houston Texas USA
- Department of Biology and Biochemistry University of Houston Houston Texas USA
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2022-12-08
- Volume
- 120
- Issue
- 2
- Pages
- 482-490
- ISSN
- 0006-3592
- 1097-0290
- Cited by
- 4
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review