Graduated, static, external compression of the lower limb: A physiological assessment
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Summary: A five-chambered pneumatic vinyl sleeve was used to determine the optimum pressure range of graduated, static, external compression of the lower limb, which would be most beneficial in increasing deep venous velocity. The effects of four different ranges of pressure upon deep venous velocity (technitium-99), calf muscle blood flow (xenon-133) and subcutaneous tissue flow (sodium-24) were measured in recumbent patients. The pressure range 18, 14, 8, 10, 8 mmHg produced a significant increase in mean deep venous velocity (P < 0·02) without any consequent impairment of either calf muscle blood flow or subcutaneous tissue flow. A higher pressure range of 30, 26, 14, 18, 12 mmHg also produced an increase in mean deep venous velocity, but caused a significant impairment of calf subcutaneous tissue flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of regional circulation by the local clearance of radioactive sodium
Kety, S. S. (1949) · American Heart Journal · doi:10.1016/0002-8703(49)90845-5 · Cited by 530
MEASUREMENT OF BLOOD-FLOW THROUGH SKELETAL MUSCLE BY INTRAMUSCULAR INJECTION OF XENON-133
Lassen, N. A., Lindbjerg, J., & Munck, O. (1964) · The Lancet · doi:10.1016/s0140-6736(64)91518-1 · Cited by 476
TRIPLET PREGNANCY AFTER PULSATILE ADMINISTRATION OF GONADOTROPIN RELEASING HORMONE
Bogchelman, D., Lappöhn, R. E., & Janssens, J. (1982) · The Lancet · doi:10.1016/s0140-6736(82)91180-1 · Cited by 378
PREVENTION OF FATAL POSTOPERATIVE PULMONARY EMBOLISM BY LOW-DOSE HEPARIN
Gruber, U., Duckert, F., Fridrich, R., Rem, J., Torhorst, J., Kakkar, V. V., Corrigan, T. P., Fossard, D. P., Sutherland, I., & Thirlwell, J. (1977) · The Lancet · doi:10.1016/s0140-6736(77)91213-2 · Cited by 221
Self-citationSigel, B. (1975) · Archives of Surgery · doi:10.1001/archsurg.1975.01360080037005 · Cited by 214
PREVENTION OF FATAL POSTOPERATIVE PULMONARY EMBOLISM BY LOW DOSES OF HEPARIN
MULTICENTRE TRIAL, A. I. (1976) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-197603000-00014 · Cited by 176
Plasma alkaline phosphatase activity in preterm neonates.
Schilling, R., Haschke, F., Kovarik, J. J., & Woloszczuk, W. (1982) · PubMed · Cited by 161
Kline, A., Hughes, L. E., Campbell, H., Williams, A., Zlosnick, J., & Leach, K. G. (1975) · BMJ · doi:10.1136/bmj.2.5963.109 · Cited by 102
Sabri, S., Roberts, V. C., & Cotton, L. T. (1971) · BMJ · doi:10.1136/bmj.4.5784.394 · Cited by 73
Chant, A. D. B. (1972) · British journal of surgery · doi:10.1002/bjs.1800590713 · Cited by 24
Cited by
Investigation of Chronic Venous Insufficiency: A Consensus Statement
Nicolaides, A. N. (2000) · Circulation · doi:10.1161/01.cir.102.20.e126 · Cited by 945
Recovery in Soccer: Part II—Recovery Strategies
Nédélec, M., McCall, A., Carling, C., Legall, F., Berthoin, S., & Dupont, G. (2013) · Sports Medicine · doi:10.1007/s40279-012-0002-0 · Cited by 328
Graduated compression stockings in the prevention of venous thromboembolism
Agu, O., Hamilton, G., & Baker, D. (1999) · Journal of British Surgery · doi:10.1046/j.1365-2168.1999.01195.x · Cited by 296
Compression Garments and Exercise: Garment Considerations, Physiology and Performance
MacRae, B. A., Cotter, J. D., & Laing, R. M. (2011) · Sports Medicine · doi:10.2165/11591420-000000000-00000 · Cited by 269
Evidence-Based Compression: Prevention of Stasis and Deep Vein Thrombosis
Morris, R. J., & Woodcock, J. P. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000109149.77194.6c · Cited by 221
“Much of the initial enthusiasm for compression stockings was supported by physiological evidence from radiopharmaceutical clearance,([63-65]) invasive electromagnetic flowmeters,([7]) and early Doppler ultrasound,([66,67]) that intermittent compression increased resting venous blood flow velocities.”
BackgroundRecovery in Soccer: Part I — Post-Match Fatigue and Time Course of Recovery
Nédélec, M., McCall, A., Carling, C., Legall, F., Berthoin, S., & Dupont, G. (2012) · Sports Medicine · doi:10.1007/bf03262308 · Cited by 210
Bringing Light into the Dark: Effects of Compression Clothing on Performance and Recovery
Born, D.-P., Sperlich, B., & Holmberg, H.-C. (2013) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.8.1.4 · Cited by 168
Influence of compression hosiery on physiological responses to standing fatigue in women
KRAEMER, W. J., VOLEK, J. S., BUSH, J. A., GOTSHALK, L. A., WAGNER, P. R., G??MEZ, A. L., ZATSIORSKY, V. M., DUZRTE, M., RATAMESS, N. A., MAZZETTI, S. A., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200011000-00006 · Cited by 118
(2006) · PubMed · Cited by 89
O’Riordan, S. F., Bishop, D. J., Halson, S. L., & Broatch, J. R. (2022) · Scientific Reports · doi:10.1038/s41598-022-21029-2 · Cited by 14
Metadata
- Authors
- Lawrence, D., & Kakkar, V. V.
- Venue
- Journal of British Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 1980-02-01
- Volume
- 67
- Issue
- 2
- Pages
- 119-121
- ISSN
- 0007-1323 (ISSN-L)
- 1365-2168
- OpenAlex
- W2084035091
- Cited by
- 217
- References
- 11
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.