Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm

Drury, D, Michaels, J A, Jones, L, Ayiku, L·2005·British Journal of Surgery

Abstract

Background: Conventional management of abdominal aortic aneurysm (AAA) is by open repair and is associated with a mortality rate of 2–6 per cent. Endovascular aneurysm repair (EVAR) is an alternative technique first introduced in 1991. A systematic review was undertaken of the evidence for the safety and efficacy of elective EVAR in the management of asymptomatic infrarenal AAA. Methods: Thirteen electronic bibliographical databases were searched, covering biomedical, health-related, science and social science literature. Outcomes were assessed with respect to efficacy (successful deployment, technical success, conversion rates and secondary intervention rates) and safety (30-day mortality rate, procedure morbidity rates and technical issues—endoleaks, graft thrombosis, stenosis and migration). Results: Of 606 reports identified, 61 met the inclusion criteria (three randomized and 15 non-randomized controlled trials, and 43 uncontrolled studies). There were 29 059 participants in total; 19 804 underwent EVAR. Deployment was successful in 97·6 per cent of cases. Technical success (complete aneurysm exclusion) was 81·9 per cent at discharge and 88·8 per cent at 30 days. Secondary intervention to treat endoleak or maintain graft patency was required in 16·2 per cent of patients. Mean stay in the intensive care unit and mean hospital stay were significantly shorter following EVAR. The 30-day mortality rate for EVAR was 1·6 per cent (randomized controlled trials) and 2·0 per cent in nonrandomized trials and case series. Technical complications comprised stent migration (4·0 per cent), graft limb thrombosis (3·9 per cent), endoleak (type I, 6·8 per cent; type II, 10·3 per cent; type III, 4·2 per cent) and access artery injury (4·8 per cent). Discussion: EVAR is technically effective and safe, with lower short-term morbidity and mortality rates than open surgery. However, there is a need for extended follow-up as the long-term success of EVAR in preventing aneurysm-related deaths is not yet known.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bjs.5123

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Drury, D., Michaels, J. A., Jones, L., & Ayiku, L.
Venue
British Journal of Surgery
Published
2005-07-20
Volume
92
Issue
8
Pages
937-946
ISSN
  • 0007-1323 (ISSN-L)
  • 1365-2168
OpenAlex
W2002486165
Cited by
207
References
1
FWCI
3.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.