Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management

Open access
Daye, Dania, Walker, T. Gregory·2018·Cardiovascular Diagnosis and Therapy

Abstract

In recent decades, endovascular aneurysm repair or endovascular aortic repair (EVAR) has become an acceptable alternative to open surgery for the treatment of thoracic and abdominal aortic aneurysms and other aortic pathologies such as the acute aortic syndromes (e.g., penetrating aortic ulcer, intramural hematoma, dissection). Available data suggest that endovascular repair is associated with lower perioperative 30-day all-cause mortality as well as a significant reduction in perioperative morbidity when compared to open surgery. Additionally, EVAR leads to decreased blood loss, eliminates the need for cross-clamping the aorta and has shorter recovery periods than traditional surgery. It is currently the preferred mode of treatment of thoracic and abdominal aortic aneurysms in a subset of patients who meet certain anatomic criteria conducive to endovascular repair. The main disadvantage of EVAR procedures is the high rate of post-procedural complications that often require secondary re-intervention. As a result, most authorities recommend lifelong imaging surveillance following repair. Available surveillance modalities include conventional radiography, computed tomography, magnetic resonance angiography, ultrasonography, nuclear imaging and conventional angiography, with computed tomography currently considered to be the gold standard for surveillance by most experts. Following endovascular abdominal aortic aneurysm (AAA) repair, the rate of complications is estimated to range between 16% and 30%. The complication rate is higher following thoracic EVAR (TEVAR) and is estimated to be as high as 38%. Common complications include both those related to the endograft device and systemic complications. Device-related complications include endoleaks, endograft migration or collapse, kinking and/or stenosis of an endograft limb and graft infection. Post-procedural systemic complications include end-organ ischemia, cerebrovascular and cardiovascular events and post-implantation syndrome. Secondary re-interventions are required in approximately 19% to 24% of cases following endovascular abdominal and thoracic aortic aneurysm repair respectively. Typically, most secondary reinterventions involve the use of percutaneous techniques such as placement of cuff extension devices, additional endograft components or stents, enhancement of endograft fixation, treatment of certain endoleaks using various embolization techniques and embolic agents and thrombolysis of occluded endograft components. Less commonly, surgical conversion and/or open surgical modification are required. In this article, we provide an overview of the most common complications that may occur following endovascular repair of thoracic and AAAs. We also summarize the current surveillance recommendations for detecting and evaluating these complications and discuss various current secondary re-intervention approaches that may typically be employed for treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/cdt.2017.09.17

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Cited by

See all 266

Metadata

Authors
Daye, D., & Walker, T. G.
Venue
Cardiovascular Diagnosis and Therapy
Published
2018-04
Volume
8
Issue
S1
Pages
S138-S156
ISSN
  • 2223-3652 (ISSN-L)
  • 2223-3660
OpenAlex
W2762687029
Cited by
266
References
47
FWCI
9.98
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. https://app.cochat.ai/papers/10.21037/cdt.2017.09.17
The paper
Daye, D., & Walker, T. G. (2018). Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. Cardiovascular Diagnosis and Therapy. https://doi.org/10.21037/cdt.2017.09.17

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.