Cited by 118Effects and risks of endocrine disrupting chemicalsAnalytical chemistry methods developmentAnalytical Chemistry and Chromatography

Determination of bisphenol A in rat brain by microdialysis and column switching high‐performance liquid chromatography with fluorescence detection

Sun, Yen, Nakashima, Mihoko N., Takahashi, Masakatsu, Kuroda, Naotaka, Nakashima, Kenichiro·2002·Biomedical Chromatography

Abstract

A sensitive column switching HPLC-fluorescence detection for determination of bisphenol A (BPA) in rat brain by coupling with microdialysis was developed. A microdialysis probe was inserted into the hypothalamus of rat brain and an artificial cerebrospinal fluid was used for perfusion. BPA in brain dialysate was subjected to a fluorescent derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl), and the excess reagent was removed by a column-switching technique. Separation was carried out on two ODS semimicro-columns with the mobile phase of acetonitrile-H(2)O-methanol-tetrahydrofuran (55:10:35:2.5, v/v) and acetonitrile-0.1 M acetate buffer (pH 3.0)-methanol (35:10:55, v/v) at a flow rate of 0.10 and 0.15 mL/min for a precolumn and a separation column, respectively. Fluorescence intensity was monitored at 475 nm with excitation of 350 nm. BPA could be sensitively detected at 0.3 ppb in 60 micro L brain microdialysate at a signal-to-noise ratio of 3. By the proposed method, concentrations of BPA in rat brain and plasma were monitored for 8 h after single i.v. or oral administration. It is proved that BPA is capable of penetrating the blood-brain barrier. The ratio of the area under the concentration-time curve of BPA in rat brain to that in blood was estimated to be about 3.0-3.8%.

Integrity signals

Registry

Crossref · 10.1002/bmc.161

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In the hippocampus, spine head size can be increased after LTP induction through AMPA receptor recruitment at synapses.

    “In the hippocampus, the spine head size could be increased after LTP induction through AMPA receptor recruitment at synapses.29”

Cited by

Sorted by citations

Authors
Sun, Y., Nakashima, M. N., Takahashi, M., Kuroda, N., & Nakashima, K.
Affiliations
Nagasaki University (JP)
Corresponding author
Nakashima, Kenichiro
Venue
Biomedical Chromatography
Publisher
Wiley
Published
2002-03-28
Volume
16
Issue
5
Pages
319-326
ISSN
  • 0269-3879 (ISSN-L)
  • 1099-0801
OpenAlex
W2159054307
Cited by
118
References
0
Citations by year
2026: 3 · 2025: 3 · 2024: 8 · 2023: 7 · 2022: 9 · 2021: 7 · 2020: 8 · 2019: 5 · 2018: 3 · 2017: 5 · 2016: 5 · 2015: 3 · 2014: 5 · 2013: 6 · 2012: 8
FWCI
2.30
Type
journal article
Language
en
Open access
closed
Locations
  • Biomedical Chromatography (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Effects and risks of endocrine disrupting chemicals
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
Keywords
bisphenol A, cerebral microdialysis, column switching, fluorescent derivatization, blood-brain barrier penetration, rat brain, hypothalamus, plasma pharmacokinetics, endocrine disruptors
MeSH terms
Bisphenol A Compounds, Animals, Benzhydryl Compounds, Biological Availability, Brain, Chromatography, High Pressure Liquid, Male, Phenols, Sensitivity and Specificity, Spectrometry, Fluorescence, Reproducibility of Results, Rats, Wistar, Microdialysis, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review