In vivo evaluation of CYP1A2, CYP2A6, NAT‐2 and xanthine oxidase activities in a Greek population sample by the RP‐HPLC monitoring of caffeine metabolic ratios

Begas, E., Kouvaras, E., Tsakalof, A., Papakosta, S., Asprodini, E. K. · 2007 · Biomedical Chromatography
Cited by 97

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A RP‐HPLC method was developed for the assessment of caffeine and its metabolites in urine and was used for the evaluation of the CYP1A2, CYP2A6, xanthine oxidase (XO) and N‐acetyl‐transferase‐2 (NAT‐2) in vivo activities in 44 Greek volunteers (21 men, 23 women). Spot urine samples were analyzed 6 h after 200 mg caffeine consumption, following a 30 h methylxantine‐free diet. The major urinary caffeine metabolites are 1‐methyluric acid (1U), 5‐acetylamino‐6‐formylamino‐3‐methyluracil (AFMU), 1‐methylxanthine (1X), 1,7‐dimethyluric acid (17U) and 1,7‐dimethylxanthine (17X). CYP1A2, CYP2A6, XO and NAT‐2 activities were estimated from the metabolic ratios (AFMU + 1U + 1X)/17U, 17U/17X, 1U/(1X + 1U) and AFMU/(AFMU + 1U + 1X), respectively. Metabolites and internal standard were extracted with chloroform/isopropanol (85:15, v/v) and separated on a C 18 column by an isocratic HPLC system using a two‐step elution with manual switch from solvent A (0.1% acetic acid–methanol–acetonitrile, 92:4:5 v/v) to solvent B (0.1% acetic acid–methanol, 60:40, v/v), and detected at 280 nm. The method exhibited adequate metabolite separation (resolution factors >1.48), accuracy (94.1–106.3%) and intraday and interday precision <8.02 and <8.78%, respectively (n = 6). Smoking affected only CYP1A2, whereas gender had no effect in any enzyme activity. NAT‐2 exhibited bimodal distribution, 63.6% of volunteers being slow acetylators. The developed RP‐HPLC method was fully validated and successfully applied for the evaluation of CYP1A2, CYP2A6, XO and NAT‐2 activities. Copyright © 2007 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bmc.736

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 97

Metadata

Authors
Begas, E., Kouvaras, E., Tsakalof, A., Papakosta, S., & Asprodini, E. K.
Venue
Biomedical Chromatography
Publisher
Wiley
Published
2007-01-15
Volume
21
Issue
2
Pages
190-200
ISSN
  • 0269-3879 (ISSN-L)
  • 1099-0801
OpenAlex
W2079488969
Cited by
97
References
1
FWCI
2.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo evaluation of CYP1A2, CYP2A6, NAT‐2 and xanthine oxidase activities in a Greek population sample by the RP‐HPLC monitoring of caffeine metabolic ratios. https://app.cochat.ai/papers/10.1002/bmc.736
The paper
Begas, E., Kouvaras, E., Tsakalof, A., Papakosta, S., & Asprodini, E. K. (2007). In vivo evaluation of CYP1A2, CYP2A6, NAT‐2 and xanthine oxidase activities in a Greek population sample by the RP‐HPLC monitoring of caffeine metabolic ratios. Biomedical Chromatography. https://doi.org/10.1002/bmc.736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.