The DOI matches its Crossref record.
Precise measurement of total body water using trace quantities of deuterium oxide
Abstract
This study was undertaken to investigate the possibility of measuring total body water in human subjects to better than +/-0.5%. Accurate serial estimates of total body water were required to complement densitometric and anthropometric measurements used to monitor body compositional changes in obese patients undergoing dietary or surgical weight reduction therapy. The method required the oral administration of 1-2 g of deuterium oxide and the analysis of pre-dose and respective equilibrated samples of urine, plasma or saliva. The sample size required for analysis was 5 microliter and the conversion of gaseous phase was accomplished using a uranium reduction furnace. Isotopic enrichment of samples was measured using a mass spectrometer incorporating several features designed to cope with problems inherent in H2/H2H isotopic analysis. Reproducibility of sample preparation and accuracy of the mass spectrometer were tested using international standards and shown to give an overall sensitivity of 2 parts in 10(7) for the determination of deuterium in H2O/H2HO mixtures. This precision has enabled us to demonstrate that isotopic fractionation of deuterium with respect to hydrogen occurs within the body and expands the potential use of this isotope for quantitative biochemical studies in the human subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Total body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
NEW METHOD FOR MEASURING MILK INTAKES IN BREAST-FED BABIES
Coward, W. A., Whitehead, R. G., Sawyer, M. B., Prentice, A. M., & Evans, J. (1979) · The Lancet · doi:10.1016/s0140-6736(79)90177-6 · Cited by 351
Wickramasinghe, V. P., Lamabadusuriya, S. P., Cleghorn, G. J., & Davies, P. S. W. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602835 · Cited by 53
Metadata
- Authors
- Halliday, D., & Miller, A. G.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1977-04
- Volume
- 4
- Issue
- 2
- Pages
- 82-87
- ISSN
- 1076-5174 (ISSN-L)
- 1052-9306
- 1096-9888
- OpenAlex
- W2043706650
- Cited by
- 164
- References
- 0
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precise measurement of total body water using trace quantities of deuterium oxide. https://app.cochat.ai/papers/10.1002/bms.1200040205
- The paper
- Halliday, D., & Miller, A. G. (1977). Precise measurement of total body water using trace quantities of deuterium oxide. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200040205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.