Cited by 666Body Composition Measurement TechniquesMuscle metabolism and nutritionChemical Reactions and Isotopes

Total body water measurement in humans with 18O and 2H labeled water

Schoeller, D A, van Santen, E, Peterson, D W, Dietz, W, Jaspan, J, Klein, P D·1980·The American Journal of Clinical Nutrition

Abstract

Deuterium or tritium labeled water traditionally has been used for the measurement of total body water by application of the dilution principle. However, these methods have not enjoyed wide clinical use. The use of deuterium is hampered by the tedious and time consuming nature of the analysis while the use of tritium involves a radiation hazard. In addition, exchange of the label with nonaqueous hydrogen in the body raises questions about the accuracy of total body water values. To determine if water labeled with the stable isotope 18O can yield faster and more accurate results, total body water was measured simultaneously using water labeled with both 18O and 2H. The 18O and 3H dilutions were measured by mass spectrometry. The relative precision of the body water value using the 18O method was 2% for both serum and breath analysis. The 18O was fully equilibrated within 2 to 3 hr after administration, and results from the analysis of breath CO2 could be readily obtained within 1 hr after sampling. The H2(18)O dilution space averaged 3.0% (SE = 0.4) less than the 2HHO dilution space, because the latter exchanges with nonaqueous hydrogen. For this reason, the H2(18)O dilution should be a more accurate measure of total body water than the 3HHO dilution.

Integrity signals

Registry

Crossref · 10.1093/ajcn/33.12.2686

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The reference method measured total body water by stable-isotope dilution with deuterium and 18O; fat-free mass was then derived from total body water with a hydration factor of 0.73.

    “Total body water was measured as a constituent of the measurement of total energy expenditure by doubly labeled water, using dilution with stable isotopes, i.e., the average of total body water spaces as measured by deuterium and 18oxygen was used as the reference method (21). Fat-free mass was calculated from total body water using a hydration constant (0.73) (22).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D.
Affiliations
  • Hewlett-Packard (United States) (US)
  • Massachusetts Institute of Technology (US)
Venue
The American Journal of Clinical Nutrition
Publisher
Elsevier BV
Published
1980-12
Volume
33
Issue
12
Pages
2686-2693
ISSN
0002-9165 (ISSN-L)
OpenAlex
W1808407909
Cited by
666
References
30
Citations by year
2026: 6 · 2025: 9 · 2024: 5 · 2023: 4 · 2022: 15 · 2021: 9 · 2020: 14 · 2019: 11 · 2018: 13 · 2017: 13 · 2016: 6 · 2015: 20 · 2014: 9 · 2013: 12 · 2012: 15
FWCI
3.23
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Clinical Nutrition (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Muscle metabolism and nutrition
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Chemical Reactions and Isotopes
Keywords
total body water, dilution method, stable isotope tracers, serum dilution, mass spectrometry
MeSH terms
Body Water, Breath Tests, Carbon Dioxide, Deuterium, Female, Humans, Male, Obesity, Oxygen Isotopes, Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review