A microprocessor controlled mass spectrometer for the fully automated purification and isotopic analysis of breath carbon dioxide
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Breath tests that measure the oxidative utilization of 13C labeled substrates have been shown to be clinically useful, but have failed to gain wide acceptance because of the slow and costly isotopic analysis of the breath samples. Therefore we have developed a fully automated, microprocessor controlled CO2 purification and isotopic analysis system. The breath CO2 is cryogenically purified by passage through cold traps of -94 degrees C and -196 degrees to condense water and CO2, respectively. The CO2 is intorduced into a dual inlet, peak-stepping mass spectrometer and analyzed for isotopic content by comparison with a known standard. Thirty samples can be analyzed without operator intervention. Analysis time average 14 minutes per sample, and the analysis has a precision of 0.3% which corresponds to 3 parts excess 13C per 10(6) parts CO2. The speed of analysis is comparable with scintillation counting and permits next day reporting of clinical breath test results. The precision is sufficient for clinical applications as it is less than 0.7% isotopic variation in basal breath CO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craig, H. (1957) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(57)90024-8 · Cited by 4,170
The geochemistry of the stable carbon isotopes
Craig, H. (1953) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(53)90001-5 · Cited by 1,965
Cited by
CAMPYLOBACTER PYLORI DETECTED NONINVASIVELY BY THE 13C-UREA BREATH TEST
Graham, D., Evans, D., Alpert, L., Klein, P., Evans, D., Opekun, A., & Boutton, T. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92145-3 · Cited by 711
Self-citationTotal body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
Self-citationHuman growth hormone prevents the protein catabolic side effects of prednisone in humans.
Horber, F. F., & Haymond, M. W. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114694 · Cited by 407
Mauras, N., Hayes, V., Welch, S., Rini, A., Helgeson, K., Dokler, M., Veldhuis, J. D., & Urban, R. J. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.6.4892 · Cited by 368
Schoeller, D. A., Klein, P. D., Watkins, J. B., Heim, T., & MacLean, W. C. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.11.2375 · Cited by 222
Self-citation
Metadata
- Authors
- Schoeller, D. A., & Klein, P. D.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1979-08
- Volume
- 6
- Issue
- 8
- Pages
- 350-355
- ISSN
- 1076-5174 (ISSN-L)
- 0306-042X
- 1096-9888
- OpenAlex
- W2032685655
- Cited by
- 72
- References
- 2
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.