Gas chromatography—stable isotope ratio analysis at natural abundance levels
The DOI matches its Crossref record.
Abstract
In recent years stable isotopes have begun to replace radioisotopes as tracers in metabolic studies. However, these are relatively expensive in the enrichments and quantities required by either conventional gas chromatography/mass spectrometry (GC/MS) or stable isotope ratio analysis (SIRA), the former having good sensitivity but low precision and the latter low sensitivity with more than adequate precision. We describe here a technique for 13C which achieves an appropriate balance between precision and sensitivity for such studies. A combustion interface is placed between the output from a capillary gas chromatograph and a dual collector SIRA mass spectrometer. Compounds eluting from the gas chromatograph are converted into discrete pulses of CO2 gas and intensities of 13CO2 and 12CO2 are measured simultaneously. Typically, 13C relative abundances can be obtained from 0.8 nmol of a C10 compound (8 nmol CO2) with a precision (1SD) of better than 1‰ (0.0011 at.%13C). This permits a reduction by at least a factor of 10 in the quantity of tracer required compared with conventional methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applied gas chromatography coupled to isotope ratio mass spectrometry
Meier-Augenstein, W. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)01057-7 · Cited by 425
DETERMINATION OF STABLE ISOTOPE RATIOS IN FOOD ANALYSIS
Rossmann, A. (2001) · Food Reviews International · doi:10.1081/fri-100104704 · Cited by 320
Boutton, T. W. (1991) · Carbon Isotope Techniques · doi:10.1016/b978-0-12-179730-0.50015-1 · Cited by 315
Elsner, M., Jochmann, M. A., Hofstetter, T. B., Hunkeler, D., Bernstein, A., Schmidt, T. C., & Schimmelmann, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5683-y · Cited by 276
Isotope‐ratio detection for gas chromatography
Sessions, A. L. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600002 · Cited by 271
Metadata
- Authors
- Barrie, A., Bricout, J., & Koziet, J.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1984-11
- Volume
- 11
- Issue
- 11
- Pages
- 583-588
- ISSN
- 1076-5174 (ISSN-L)
- 0306-042X
- 1096-9888
- OpenAlex
- W1967895542
- Cited by
- 112
- References
- 0
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gas chromatography—stable isotope ratio analysis at natural abundance levels. https://app.cochat.ai/papers/10.1002/bms.1200111106
- The paper
- Barrie, A., Bricout, J., & Koziet, J. (1984). Gas chromatography—stable isotope ratio analysis at natural abundance levels. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200111106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.