Rapid sample throughput for biomedical stable isotope tracer studies
The DOI matches its Crossref record.
Abstract
Typical 13C or 15N tracer studies generate large numbers of samples. Instrumentation capable of rapid automated analysis is therefore of importance as a practical alternative to conventional isotope methodology. Although biomedical sample nature is diverse, experimenters often require analysis of substrates and products of particular biochemical pathways. Clearly, reaction products can contain considerably less isotope tracer than precursors. Analytical techniques thus need to accommodate samples of widely varying nature, size and isotope enrichment. In the clinical field, where stable isotopes are increasingly used to study protein, carbohydrate and fat metabolism, analysis of the isotope ratio of a substrate infused into the plasma and a product of its metabolism is often required. Conventional analytical approaches demand access to two mass spectrometers: isotope ratio mass spectrometry (IRMS) for isotope analysis of the relatively large concentrations of low-enrichment metabolic product, and gas chromatography/mass spectrometry (GC/MS) for analysis of the infused substrate often present at high enrichment but low concentration offers a practical alternative to the conventional approaches that is rapid and automatic. In addition to providing a considerably less complex and costly alternative to conventional instrumentation, a single CF-IRMS instrument can also analyse small quantities of low-enrichment metabolites with superior performance than either of the alternative approaches. CF-IRMS is illustrated using results from constant-infusion studies in human protein and fat metabolism which require measurement of the isotope enrichment in submicromolar quantities of plasma substrates together with analysis of larger quantities of their oxidation products, urinary nitrogen and breath CO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vollenweider, P., Tappy, L., Randin, D., Schneiter, P., Jéquier, E., Nicod, P., & Scherrer, U. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116542 · Cited by 321
(1997) · Advances in Ecological Research · doi:10.1016/s0065-2504(08)60008-2 · Cited by 255
Lacroix, M., Bos, C., Léonil, J., Airinei, G., Luengo, C., Daré, S., Benamouzig, R., Fouillet, H., Fauquant, J., Tomé, D., et al. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/84.5.1070 · Cited by 194
“Serum urea was isolated by using a Na form of the cation exchange resin (Biorad Dowex, mesh 100–200; Interchim, Montluçon, France), as described by Preston and McMillan (14) in the presence of urease (EC 3.”
MethodInfluentialGausserès, N., Mahé, S., Benamouzig, R., Luengo, C., Ferriere, F., Rautureau, J., & Tomé, D. (1997) · The Journal of Nutrition · doi:10.1093/jn/127.6.1160 · Cited by 60
Brenna (1997) · doi:10.1002/(sici)1098-2787(1997)16:5<227::aid-mas1>3.0.co;2-j
Metadata
- Authors
- Preston, T., & McMillan, D. C.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1988-10
- Volume
- 16
- Issue
- 1-12
- Pages
- 229-235
- ISSN
- 1076-5174 (ISSN-L)
- 1052-9306
- 1096-9888
- OpenAlex
- W2007481102
- Cited by
- 79
- References
- 0
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid sample throughput for biomedical stable isotope tracer studies. https://app.cochat.ai/papers/10.1002/bms.1200160142
- The paper
- Preston, T., & McMillan, D. C. (1988). Rapid sample throughput for biomedical stable isotope tracer studies. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200160142
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.