CoChat

Rapid sample throughput for biomedical stable isotope tracer studies

Preston, T., McMillan, D. C. · 1988 · Biological Mass Spectrometry
Cited by 79

The DOI matches its Crossref record.

Abstract

Typical 13C or 15N tracer studies generate large numbers of samples. Instrumentation capable of rapid automated analysis is therefore of importance as a practical alternative to conventional isotope methodology. Although biomedical sample nature is diverse, experimenters often require analysis of substrates and products of particular biochemical pathways. Clearly, reaction products can contain considerably less isotope tracer than precursors. Analytical techniques thus need to accommodate samples of widely varying nature, size and isotope enrichment. In the clinical field, where stable isotopes are increasingly used to study protein, carbohydrate and fat metabolism, analysis of the isotope ratio of a substrate infused into the plasma and a product of its metabolism is often required. Conventional analytical approaches demand access to two mass spectrometers: isotope ratio mass spectrometry (IRMS) for isotope analysis of the relatively large concentrations of low-enrichment metabolic product, and gas chromatography/mass spectrometry (GC/MS) for analysis of the infused substrate often present at high enrichment but low concentration offers a practical alternative to the conventional approaches that is rapid and automatic. In addition to providing a considerably less complex and costly alternative to conventional instrumentation, a single CF-IRMS instrument can also analyse small quantities of low-enrichment metabolites with superior performance than either of the alternative approaches. CF-IRMS is illustrated using results from constant-infusion studies in human protein and fat metabolism which require measurement of the isotope enrichment in submicromolar quantities of plasma substrates together with analysis of larger quantities of their oxidation products, urinary nitrogen and breath CO2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bms.1200160142

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 79

Metadata

Authors
Preston, T., & McMillan, D. C.
Venue
Biological Mass Spectrometry
Publisher
Wiley
Published
1988-10
Volume
16
Issue
1-12
Pages
229-235
ISSN
  • 1076-5174 (ISSN-L)
  • 1052-9306
  • 1096-9888
OpenAlex
W2007481102
Cited by
79
References
0
FWCI
2.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid sample throughput for biomedical stable isotope tracer studies. https://app.cochat.ai/papers/10.1002/bms.1200160142
The paper
Preston, T., & McMillan, D. C. (1988). Rapid sample throughput for biomedical stable isotope tracer studies. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200160142

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.