A simplified method for deuterium/hydrogen isotope ratio measurements on water samples of biological origin
The DOI matches its Crossref record.
Abstract
Equilibration of hydrogen gas with the water in a variety of biological sample materials was carried out in Vacutainers using platinum-on-alumina catalyst physically isolated from the liquid water. The equilibration takes 3 days at room temperature--much slower than with catalysts which float on the water surface--but this reduces the short-term temperature sensitivity of the procedure, and the inexpensive materials used allow convenient disposal of biologically contaminated samples after analysis. The slow equilibration also allows time for complete exchange with water contained in a complex sample matrix such as plant stems or soil without the need for prior isolation of the water sample. The method has particular application in studies of human total body water where repeated studies can be carried out over a short time period without the need to wait for the previous dose to wash out. Water turnover rates from total diurnal energy expenditure studies measured by this method were not significantly different from those obtained by the zinc reduction method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moses, A. W. G., Slater, C., Preston, T., Barber, M. D., & Fearon, K. C. H. (2004) · British Journal of Cancer · doi:10.1038/sj.bjc.6601620 · Cited by 452
Physical Activity Levels Are Low in Free‐Living Adults with Chronic Paraplegia
Buchholz, A. C., McGillivray, C. F., & Pencharz, P. B. (2003) · Obesity Research · doi:10.1038/oby.2003.79 · Cited by 220
“, Crewe, UK) after equilibration with hydrogen gas (”
BackgroundBuchholz, A. C., McGillivray, C. F., & Pencharz, P. B. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.2.371 · Cited by 194
“Plasma samples were analyzed for their (2)H2O content by using an isotope ratio mass spectrometer (CF-IRMS, model ANCA GSL; Europa Scientific Inc, Crewe, United Kingdom) after equilibration with hydrogen gas (27).”
MethodSilva, A. M., Júdice, P. B., Matias, C. N., Santos, D. A., Magalhães, J. P., St-Onge, M.-P., Gonçalves, E. M., Armada-da-Silva, P., & Sardinha, L. B. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0253 · Cited by 32
“Urine and diluted dose samples were prepared for 1H/2H analysis using the equilibration technique (Scrimgeour et al. 1993).”
MethodSiervo, M., Faber, P., Lara, J., Gibney, E. R., Milne, E., Ritz, P., Lobley, G. E., Elia, M., Stubbs, R. J., & Johnstone, A. M. (2015) · Metabolism · doi:10.1016/j.metabol.2015.03.011 · Cited by 31
“[28] Scrimgeour CM, Rollo MM, Mudambo SMKT, Handley LL, Prosser SJ.”
BackgroundMethod
Metadata
- Authors
- Scrimgeour, C. M., Rollo, M. M., Mudambo, S. M. K. T., Handley, L. L., & Prosser, S. J.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 22
- Issue
- 7
- Pages
- 383-387
- ISSN
- 1076-5174 (ISSN-L)
- 1052-9306
- 1096-9888
- OpenAlex
- W2091375818
- Cited by
- 113
- References
- 0
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simplified method for deuterium/hydrogen isotope ratio measurements on water samples of biological origin. https://app.cochat.ai/papers/10.1002/bms.1200220704
- The paper
- Scrimgeour, C. M., Rollo, M. M., Mudambo, S. M. K. T., Handley, L. L., & Prosser, S. J. (1993). A simplified method for deuterium/hydrogen isotope ratio measurements on water samples of biological origin. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200220704
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.