Implant‐bone‐interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo
Open accessThe DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Titanium is commonly and successfully used in dental and orthopedic implants. However, patients still have to face the risk of implant failure due to various reasons, such as implant loosening or infection. The risk of implant loosening can be countered by optimizing the osteointegration capacity of implant materials. Implant surface modifications for structuring, roughening and biological activation in favor for osteogenic differentiation have been vastly studied. A key factor for a successful stable long‐term integration is the initial cellular response to the implant material. Hence, cell–material interactions, which are dependent on the surface parameters, need to be considered in the implant design. Therefore, this review starts with an introduction to the basics of cell–material interactions as well as common surface modification techniques. Afterwards, recent research on the impact of osteogenic processes in vitro and vivo provoked by various surface modifications is reviewed and discussed, in order to give an update on currently applied and developing implant modification techniques for enhancing osteointegration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hynes (2002) · doi:10.1016/s0092-8674(02)00971-6 · Cited by 8,606
Osteoinduction, osteoconduction and osseointegration
T., A., & C., J. (2001) · European Spine Journal · doi:10.1007/s005860100282 · Cited by 1,751 · cited 1×
“quality, (ii) act inhibitory for infections, and (iii) prolong the longevity of an implant.(5) Osteointegration arises from the physical and chemical interaction between the implant surface and the bone tissue.”
BackgroundEffects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 1,118
Integrins in Mechanotransduction
Katsumi, A., Orr, A. W., Tzima, E., & Schwartz, M. A. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.r300038200 · Cited by 723
Impact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701 · cited 2×
“tures of an implant, nano-patterning has been reckoned to play a crucial role for the biological response.(9,27,51) Despite that the sand”
BackgroundNano-scale modification of titanium implant surfaces to enhance osseointegration
Souza, J. C. M., Sordi, M. B., Kanazawa, M., Ravindran, S., Henriques, B., Silva, F. S., Aparicio, C., & Cooper, L. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.045 · Cited by 544 · cited 3×
“tures of an implant, nano-patterning has been reckoned to play a crucial role for the biological response.(9,27,51) Despite that the sand”
BackgroundClassification of osseointegrated implant surfaces: materials, chemistry and topography
Dohan Ehrenfest, D. M., Coelho, P. G., Kang, B.-S., Sul, Y.-T., & Albrektsson, T. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.12.003 · Cited by 541 · cited 1×
“tially characterized by its inherent chemical composition and the surface's physical and or biochemical modification(s).(38) As mentioned above, the topography describes the biomechanical and structural characteristics of the surface.”
BackgroundImplant Surface Roughness and Bone Healing: a Systematic Review
Shalabi, M. M., Gortemaker, A., Hof, M. A. V., Jansen, J. A., & Creugers, N. H. J. (2006) · Journal of Dental Research · doi:10.1177/154405910608500603 · Cited by 531 · cited 1×
“For example, osteoblasts exhibit an enhanced collagen production and calcification processes when cultured on rough surfaces.(28,29) It has also been shown that the combination of multiple length-scale fea-”
Background
Metadata
- Authors
- Stich, T., Alagboso, F., Křenek, T., Kovářík, T., Alt, V., & Docheva, D.
- Venue
- Bioengineering & Translational Medicine
- Publisher
- Wiley
- Published
- 2021-07-12
- Volume
- 7
- Issue
- 1
- Pages
- e10239-e10239
- ISSN
- 2380-6761 (ISSN-L)
- OpenAlex
- W3176123121
- Cited by
- 206
- References
- 78
- FWCI
- 25.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implant‐bone‐interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo. https://app.cochat.ai/papers/10.1002/btm2.10239
- The paper
- Stich, T., Alagboso, F., Křenek, T., Kovářík, T., Alt, V., & Docheva, D. (2022). Implant‐bone‐interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo. Bioengineering & Translational Medicine. https://doi.org/10.1002/btm2.10239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.