Cited by 25Intestinal and Peritoneal AdhesionsSurgical Sutures and Adhesivesbiodegradable polymer synthesis and properties

Sprayable tissue adhesive with biodegradation tuned for prevention of postoperative abdominal adhesions

Open access
Erdi, Metecan, Rozyyev, Selim, Balabhadrapatruni, Manogna, Saruwatari, Michele S., Daristotle, John L., Ayyub, Omar B., Sandler, Anthony D., Kofinas, Peter·2023·Bioengineering & Translational Medicine

Abstract

Adhesions are dense, fibrous bridges that adjoin tissue surfaces due to uncontrolled inflammation following postoperative mesothelial injury. A widely used adhesion barrier material in Seprafilm often fails to prevent transverse scar tissue deposition because of its poor mechanical properties, rapid degradation profile, and difficulty in precise application. Solution blow spinning (SBS), a polymer fiber deposition technique, allows for the placement of in situ tissue‐conforming and tissue‐adherent scaffolds with exceptional mechanical properties. While biodegradable polymers such as poly(lactic‐co‐glycolic acid) (PLGA) have desirable strength, they exhibit bulk biodegradation rates and inflammatory profiles that limit their use as adhesion barriers and result in poor tissue adhesion. Here, viscoelastic poly(lactide‐co‐caprolactone) (PLCL) is used for its pertinent biodegradation mechanism. Because it degrades via surface erosion, spray deposited PLCL fibers can dissolve new connections formed by inflamed tissue, allowing them to function as an effective, durable, and easy‐to‐apply adhesion barrier. Degradation kinetics are tuned to match adhesion formation through the design of PLCL blends comprised of highly adhesive “low”‐molecular weight (LMW) constituents in a mechanically robust “high”‐molecular weight (HMW) matrix. In vitro studies demonstrate that blending LMW PLCL (30% w/v) with HMW PLCL (70% w/v) yields an anti‐fibrotic yet tissue‐adhesive polymer sealant with a 14‐day erosion rate countering adhesion formation. PLCL blends additionally exhibit improved wet tissue adhesion strength (~10 kPa) over a 14‐day period versus previously explored biodegradable polymer compositions, such as PLGA. In a mouse cecal ligation model, select PLCL blends significantly reduce abdominal adhesions severity versus no treatment and Seprafilm‐treated controls.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/btm2.10335

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Fibers fabricated via solution blow spinning exhibit minimal solvent residues, have diameters ranging from the nanoscale to the microscale, and PLCL materials can be fabricated into various scaffolds via solution blow spinning for diverse biomedical fields.

    “The results showed that fibers fabricated via the SBS method exhibit minimal solvent residues, the fiber scaffolds had diameters ranging from the nanoscale to the microscale, and PLCL materials could be fabricated into various scaffolds via the SBS method for applications in diverse biomedical fields [84–87].”

    From Application of PLCL as a biodegradable polymer in biomedical engineering (2026) · cites this paper as [85]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • Sprayable PLCL-based tissue adhesive with anti-adhesion and anti-fibrotic properties effectively prevents abdominal adhesions post-surgery.

    “Erdi et al. developed a sprayable PLCL-based tissue adhesive with anti-adhesion and anti-fibrotic properties, which effectively prevented abdominal adhesions post-surgery. This was achieved by selecting PLCL of varying molecular weights and employing SBS technology [85].”

    From Application of PLCL as a biodegradable polymer in biomedical engineering (2026) · cites this paper as [85]

    The Abstract and Conclusion describe a spray-deposited PLCL blend made using SBS as a tissue-adherent, anti-fibrotic adhesion barrier. The Results (in vivo efficacy section) report significantly reduced adhesion severity in a mouse cecal-ligation model, not complete prevention of postoperative abdominal adhesions generally. (LLM, conf=0.87)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 49 · Cited by 25

Research works printed but not linked: 1

  1. [48]Q3C Impurities: Guideline for Residual Solvents. The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH); 2021:1–7. Accessed April 19, 2022. https://database.ich.org/sites/default/files/ICH_Q3C-R8_Guideline_Step4_2021_0422_1.pdf

Authors
Erdi, M., Rozyyev, S., Balabhadrapatruni, M., Saruwatari, M. S., Daristotle, J. L., Ayyub, O. B., Sandler, A. D., & Kofinas, P.
Affiliations
  • University of Maryland, College Park (US)
  • Children's National (US)
  • Koch Institute for Integrative Cancer Research At MIT (US)
Corresponding author
  • Sandler, Anthony D.
  • Kofinas, Peter
Venue
Bioengineering & Translational Medicine
Publisher
Wiley
Published
2022-05-23
Volume
8
Issue
1
Pages
e10335-e10335
ISSN
2380-6761 (ISSN-L)
OpenAlex
W4280581502
Cited by
25
References
49
Citations by year
2026: 6 · 2025: 4 · 2024: 9 · 2023: 5 · 2022: 1
FWCI
4.54
Type
journal article
Language
en
Open access
Locations
  • Bioengineering & Translational Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Institute of Biomedical Imaging and Bioengineering (R01EB019963)
Topics
  • Health Sciences › Medicine › Surgery › Intestinal and Peritoneal Adhesions
  • Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
Keywords
peritoneal adhesions, postoperative adhesion prevention, polymer blends, molecular weight control, solution blow spinning, spray deposition, antifibrotic effect, Seprafilm

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review