The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Noninvasive detection of lung cancer using exhaled breath
Open accessAbstract
Early detection of lung cancer is a key factor for increasing the survival rates of lung cancer patients. The analysis of exhaled breath is promising as a noninvasive diagnostic tool for diagnosis of lung cancer. We demonstrate the quantitative analysis of carbonyl volatile organic compounds (VOCs) and identification of lung cancer VOC markers in exhaled breath using unique silicon microreactor technology. The microreactor consists of thousands of micropillars coated with an ammonium aminooxy salt for capture of carbonyl VOCs in exhaled breath by means of oximation reactions. Captured aminooxy‐VOC adducts are analyzed by nanoelectrospray Fourier transform‐ion cyclotron resonance (FT‐ICR) mass spectrometry (MS). The concentrations of 2‐butanone, 2‐hydroxyacetaldehyde, 3‐hydroxy‐2‐butanone, and 4‐hydroxyhexenal (4‐HHE) in the exhaled breath of lung cancer patients (n = 97) were significantly higher than in the exhaled breath of healthy smoker and nonsmoker controls (n = 88) and patients with benign pulmonary nodules (n = 32). The concentration of 2‐butanone in exhaled breath of patients (n = 51) with stages II though IV non–small cell lung cancer (NSCLC) was significantly higher than in exhaled breath of patients with stage I (n = 34). The carbonyl VOC profile in exhaled breath determined using this new silicon microreactor technology provides for the noninvasive detection of lung cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Cited by
The emerging field of mobile health
Steinhubl, S. R., Muse, E. D., & Topol, E. J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3487 · Cited by 822
Metabolomics for laboratory diagnostics
Bujak, R., Struck-Lewicka, W., Markuszewski, M. J., & Kaliszan, R. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.12.017 · Cited by 430
Volatile Organic Compounds in Exhaled Breath as Fingerprints of Lung Cancer, Asthma and COPD
Ratiu, I. A., Ligor, T., Bocos-Bintintan, V., Mayhew, C. A., & Buszewski, B. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm10010032 · Cited by 320
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
VOC breath biomarkers in lung cancer
Saalberg, Y., & Wolff, M. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.05.013 · Cited by 293
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Peng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Breath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
Metadata
- Authors
- Fu, X., Li, M., Knipp, R. J., Nantz, M. H., & Bousamra, M.
- Venue
- Cancer Medicine
- Publisher
- Wiley
- Published
- 2013-11-20
- Volume
- 3
- Issue
- 1
- Pages
- 174-181
- ISSN
- 2045-7634 (ISSN-L)
- OpenAlex
- W4239778289
- Cited by
- 166
- References
- 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.