Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Novel Sensor Platform Based on Aptamer‐Conjugated Polypyrrole Nanotubes for Label‐Free Electrochemical Protein Detection

Yoon, Hyeonseok, Kim, June‐Hyung, Lee, Nahum, Kim, Byung‐Gee, Jang, Jyongsik·2008·ChemBioChem

Abstract

We first present a simple yet versatile strategy for the functionalization of polymer nanotubes in a controlled fashion. Carboxylic‐acid‐functionalized polypyrrole (CPPy) nanotubes were fabricated by using cylindrical micelle templates in a water‐in‐oil emulsion system, and the functional carboxyl groups were effectively incorporated into the polymer backbone during the polymerization by using pyrrole‐3‐carboxylic acid (P3CA) as a co‐monomer without a sophisticated functionalization process. It was noteworthy that the chemical functionality of CPPy nanotubes was readily controlled in both qualitative and quantitative aspects. On the basis of the controlled functionality of CPPy nanotubes, a field‐effect transistor (FET) sensor platform was constructed to detect specific biological entities by using a buffer solution as a liquid‐ion gate. The CPPy nanotubes were covalently immobilized onto the microelectrode substrate to make a good electrical contact with the metal electrodes, and thrombin aptamers were bonded to the nanotube surface via covalent linkages as the molecular recognition element. The selective recognition ability of thrombin aptamers combined with the charge transport property of CPPy nanotubes enabled the direct and label‐free electrical detection of thrombin proteins. Upon exposure to thrombin, the CPPy nanotube FET sensors showed a decrease in current flow, which was probably attributed to the dipole–dipole or dipole–charge interaction between thrombin proteins and the aptamer‐conjugated polymer chains. Importantly, the sensor response was tuned by adjusting the chemical functionality of CPPy nanotubes. The efficacy of CPPy nanotube FET sensors was also demonstrated in human blood serum; this suggests that they may be used for practical diagnosis applications after further optimization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cbic.200700660

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 162

Metadata

Authors
Yoon, H., Kim, J., Lee, N., Kim, B., & Jang, J.
Venue
ChemBioChem
Publisher
Wiley
Published
2008-02-21
Volume
9
Issue
4
Pages
634-641
ISSN
  • 1439-4227 (ISSN-L)
  • 1439-7633
OpenAlex
W2085417736
Cited by
162
References
1
FWCI
14.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Sensor Platform Based on Aptamer‐Conjugated Polypyrrole Nanotubes for Label‐Free Electrochemical Protein Detection. https://app.cochat.ai/papers/10.1002/cbic.200700660
The paper
Yoon, H., Kim, J., Lee, N., Kim, B., & Jang, J. (2008). A Novel Sensor Platform Based on Aptamer‐Conjugated Polypyrrole Nanotubes for Label‐Free Electrochemical Protein Detection. ChemBioChem. https://doi.org/10.1002/cbic.200700660

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.