The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Updated review of the global carotid artery stent registry
Abstract
The purpose of this article was to review and update the current status of carotid artery stent placement in the world. Surveys of major interventional centers in Europe, North and South America, and Asia were initially completed in June 1997. Subsequent updates from these 24 centers in addition to 29 new centers have been obtained to bring up to date the information. The survey asked the various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 12,392 procedures involving 11,243 patients. There was a technical success of 98.9% with 12,254 carotid arteries treated. Complications that occurred during the carotid stent placement or within a 30‐day period following placement were recorded. Overall, there was transient ischemic attack rate of 3.07%, minor strokes of 2.14%, major strokes of 1.20%, and procedure‐related deaths of 0.64%. The combined minor and major strokes and procedure‐related death rate was 3.98% based on procedure number. With nonprocedure‐related death rate of 0.77%, the total stroke and death rate was 4.75%. Subsets of questions were directed at the new use of distal embolic protection devices; there were 6,753 cases done without protection and which incurred a 5.29% rate of strokes and procedure‐related deaths. In the 4,221 cases with cerebral protection, there was a 2.23% rate of strokes and procedure‐related deaths. Restenosis rates of carotid stenting have been 2.7%, 2.6%, and 2.4% at 1, 2, and 3 years, respectively. The rate of neurologic events after stent placement has been 1.2%, 1.3%, and 1.7% at 1, 2, and 3 years, respectively. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative for vascular surgery, especially for patients who are high risk for standard carotid endarterectomy. The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have shown an improvement with technological developments, including distal embolic protection. Catheter Cardiovasc Interv 2003;60:259‐266
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Measurements of acute cerebral infarction: a clinical examination scale.
Brott, T., Adams, H. P., Olinger, C. P., Marler, J. R., Barsan, W. G., Biller, J., Spilker, J., Holleran, R., Eberle, R., & Hertzberg, V (1989) · Stroke · doi:10.1161/01.str.20.7.864 · Cited by 5,911
Endarterectomy for Asymptomatic Carotid Artery Stenosis
Walker, M. D. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03520420037035 · Cited by 4,403
Roubin, G. S., New, G., Iyer, S. S., Vitek, J. J., Al-Mubarak, N., Liu, M. W., Yadav, J., Gomez, C., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.4.532 · Cited by 713
Global experience in cervical carotid artery stent placement
Wholey, M. H., Wholey, M., Mathias, K., Roubin, G. S., Diethrich, E. B., Henry, M., Bailey, S., Bergeron, P., Dorros, G., Eles, G., et al. (2000) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(200006)50:2<160::aid-ccd2>3.0.co;2-e · Cited by 498
Self-citationAngioplasty and Stenting for Restenosis After Carotid Endarterectomy: Initial Experience
Yadav, J. S., Roubin, G. S., King, P., Iyer, S., & Vitek, J. (1996) · Stroke · doi:10.1161/01.str.27.11.2075 · Cited by 243
Cited by
Brott, T. G., Halperin, J. L., Abbara, S., Bacharach, J. M., Barr, J. D., Bush, R. L., Cates, C. U., Creager, M. A., Fowler, S. B., Friday, G., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.11.006 · Cited by 447
Does Free Cell Area Influence the Outcome in Carotid Artery Stenting?
Bosiers, M., de Donato, G., Deloose, K., Verbist, J., Peeters, P., Castriota, F., Cremonesi, A., & Setacci, C. (2007) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.09.019 · Cited by 320
Metadata
- Authors
- Wholey, M. H., Al‐Mubarek, N., & Wholey, M. H.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2003-09-23
- Volume
- 60
- Issue
- 2
- Pages
- 259-266
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2154316676
- Cited by
- 462
- References
- 6
- FWCI
- 34.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Updated review of the global carotid artery stent registry. https://app.cochat.ai/papers/10.1002/ccd.10645
- The paper
- Wholey, M. H., Al‐Mubarek, N., & Wholey, M. H. (2003). Updated review of the global carotid artery stent registry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.10645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.