The DOI matches its Crossref record.
Stenting of a renal artery stenosis achieves better relief of the obstructive lesion than balloon angioplasty
Abstract
A balloon‐expandable (Palmaz‐Schatz™) stainless steel stent was utilized following balloon angioplasty (PTRA) to determine if the obstructive lesion, using quantitative methods (automated measuring the diameter stenosis, and transstenotic peak systolic and mean pressure gradients), was significantly further reduced or abolished. Hemodynamic transstenotic gradient and stenoses measurements were made during 21 renal artery stenting procedures; prior and following PTRA, and subsequent to stent deployment. The stent sizes placed in the renal arteries were 5 mm (19%), 6 mm (67%), and 7 mm (14%). The results were as follows:magnified image The balloon‐expandable (Palmaz‐Schatz™) stent significantly further reduced, and in fact effectively abolished, the obstructive renal artery lesion in comparison to balloon angioplasty (PTRA). The stent's effectiveness with regard lesion recurrence, maintenance, and preservation of renal function; cure or improved management of hypertension; and survival will be determined by careful clinic follow‐up. © 1993 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
ESC Guidelines on the diagnosis and treatment of peripheral artery diseases
Endorsed by: the European Stroke Organisation (ESO), Authors/Task Force Members, Tendera, M., Aboyans, V., Bartelink, M.-L., Baumgartner, I., Clément, D., Collet, J.-P., Cremonesi, A., De Carlo, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr211 · Cited by 1,506
Safian, R. D., & Textor, S. C. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102083440607 · Cited by 1,068
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.009 · Cited by 1,021
Aronow, W. S., Fleg, J. L., Pepine, C. J., Artinian, N. T., Bakris, G., Brown, A. S., Ferdinand, K. C., Forciea, M. A., Frishman, W. H., Jaigobin, C., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821daaf6 · Cited by 614
Metadata
- Authors
- Dorros, G., Prince, C., & Mathiak, L.
- Venue
- Catheterization and Cardiovascular Diagnosis
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 29
- Issue
- 3
- Pages
- 191-198
- ISSN
- 0098-6569 (ISSN-L)
- 1097-0304
- OpenAlex
- W2160627300
- Cited by
- 165
- References
- 0
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stenting of a renal artery stenosis achieves better relief of the obstructive lesion than balloon angioplasty. https://app.cochat.ai/papers/10.1002/ccd.1810290304
- The paper
- Dorros, G., Prince, C., & Mathiak, L. (1993). Stenting of a renal artery stenosis achieves better relief of the obstructive lesion than balloon angioplasty. Catheterization and Cardiovascular Diagnosis. https://doi.org/10.1002/ccd.1810290304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.