The DOI matches its Crossref record.
Percutaneous closure of prosthetic paravalvular leaks: Case series and review
Abstract
BACKGROUND: Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Most are asymptomatic and benign, but some may cause symptoms due to a large regurgitant volume or hemolysis. Medical therapy is palliative, while reoperation carries significant morbidity and mortality. Percutaneous transcatheter closure techniques, now routinely applied in the management of pathological cardiac and vascular communications, may be adaptable to PVL closure, potentially offer symptomatic relief. METHODS: We reviewed our experience with attempted percutaneous closure of PVLs, using data from medical and procedural records. RESULTS: Between 2001 and 2004, 14 procedures were performed in 10 patients, all under general anesthesia, with transesophageal and radiographic guidance. Mitral (9) and aortic (1) valve replacements were involved, both mechanical and bioprosthetic. A variety of devices were used, including atrial septal occluders, patent ductus arteriosus occluders, and coils (all of label use). Six had a single procedure, which was technically successful in four: in two, the PVL could not be crossed. Four underwent a second procedure, which was technically successful in three; in one the previously deployed device was dislodged necessitating urgent, but ultimately uneventful, surgical removal and leak repair. One patient had transient severe hemolysis, which resolved after 1 week. At 1-year follow-up (9/10 pts) three had died, five had sustained symptomatic improvement while 1 patient with a residual leak still required regular blood transfusions. CONCLUSIONS: Percutaneous closure of PVLs is time-consuming but feasible in selected patients, with a reasonable degree of technical and clinical success. A second procedure may be necessary and a variety of complications can occur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
Zamorano, J. L., Badano, L. P., Bruce, C., Chan, K.-L., Gonçalves, A., Hahn, R. T., Keane, M. G., La Canna, G., Monaghan, M. J., Nihoyannopoulos, P., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.07.003 · Cited by 532
Steinberg, D. H., Staubach, S., Franke, J., & Sievert, H. (2010) · European Heart Journal Supplements · doi:10.1093/eurheartj/suq012 · Cited by 51
Metadata
- Authors
- Pate, G. E., Al Zubaidi, A., Chandavimol, M., Thompson, C. R., Munt, B. I., & Webb, J. G.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2006
- Volume
- 68
- Issue
- 4
- Pages
- 528-533
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2039039193
- Cited by
- 189
- References
- 0
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous closure of prosthetic paravalvular leaks: Case series and review. https://app.cochat.ai/papers/10.1002/ccd.20795
- The paper
- Pate, G. E., Al Zubaidi, A., Chandavimol, M., Thompson, C. R., Munt, B. I., & Webb, J. G. (2006). Percutaneous closure of prosthetic paravalvular leaks: Case series and review. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.20795
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.