SCAI consensus guidelines for device selection in femoral‐popliteal arterial interventions
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
The Society for Cardiovascular Angiography and Interventions (SCAI) has a history of prioritizing quality initiatives in the field of endovascular therapy (EVT) for peripheral artery disease (PAD). In 2017, SCAI updated the 2014 Appropriate Use Criteria (AUC) for EVT in the aorto-iliac, femoral-popliteal (FP), infra-popliteal and renal arterial circulations, promoting data-driven procedural decision making and understanding of relative risks and benefits of EVT in specific clinical and anatomic scenarios 1. In 2016, the updated AHA/ACC PAD Guidelines document provided contemporary recommendations for diagnosis and management of lower extremity PAD 2. However, these documents did not address the selection of specific devices when EVT is indicated. Device choices for EVT in the FP arterial bed remain challenging due to a wide spectrum of available endovascular device options and a paucity of comparative effectiveness data. The purpose of this first device-focused consensus document is to provide a review of comparative effectiveness data, including safety and efficacy of FP devices, and to provide clinicians with guidance and recommendations for device selection, when these devices are intended as the definitive or adjunctive therapy. This document provides recommendations applicable to devices used for EVT in FP disease. The goal is to guide clinical judgment with an emphasis on evidence-based and cost-effective utilization. This document is intended as a guide to improve decision making regarding EVT device selection for patients undergoing EVT. A balanced writing group was nominated and selected based on their EVT expertise, with consideration of relationships with industry and professional specialty or area of focus. The Writing Group Chairman and ≥50% of the members had no relevant relationships with industry (Table 1). The recommendations listed, whenever possible, were based on randomized controlled trials (RCTs) and meta-analyses, but also included registries, nonrandomized comparative studies, case series, cohort studies, and expert opinion. The writing committee chose the studies to highlight in this document; the final summary of the reviewed and most relevant clinical data is included in the Supporting Information Tables S1-S7. Abbott Vascular—advisory board Boston Scientific—advisory board Cardiovascular Systems—advisory board Cook—advisory board Gore—consultant Spectranetics—consultant, advisory board Non-Compensated Advisor: Abbott Vascular; Boston Scientific; Cordis, a Cardinal Health Company; Medtronic Compensated Advisor: Philips/Volcano; Micell; Vactronix; Venarum; American Orthotics and Prosthetics Association Equity Investment: PQ Bypass; Primacea; Gemini; eFemoral; Embolitech; Vascular Therapies; Sano V Abbott Vascular—advisory board Boston Scientific—advisory board Medtronic—advisory board Philips/Spectranetics—advisory board Abiomed—Speaker ACIST Medical—Grants/Research Support AstraZeneca—Speaker General Electric—Consultant Medtronic—Grants/Research Support Osprey Medical - Consultant Abbott Vascular—advisory board, consultant Atrium—grants/research support (national PI) Bard—grants/research support (national PI) Capture Vascular—advisory board, consultant Cardinal Health—advisory board, consultant Contego—advisory board, consultant Cook—advisory board Cruzar—advisory board, consultant, Ownership/Stock Owner/Shareholder Endospan—advisory board, consultant, Ownership/Stock Owner/Shareholder Eximo—advisory board, consultant, Ownership/Stock Owner/Shareholder Medtronic—advisory board, consultant Abbott - advisory board, consultant Boston Scientific - advisory board, consultant Phillips - advisory board, consultant ACIST Medical—Grants/Research Support Boston Scientific—Ownership/Stock Owner/Shareholder The Class (strength) of Recommendation (COR) represents the anticipated magnitude and certainty of comparative benefit for a group of devices (i.e., symptom improvement, patency, functional status, and/or quality of life) against the risks and cost of the device use based on the SCAI (modified ACC/AHA guideline recommendation) 3 classification (Table 2). The Level of Evidence (LOE) provides evidence supporting the effect of the devices on the basis of the type, quality, quantity, and consistency of data. The COR and LOE are determined independently; any COR may be paired with any LOE. Class I (Strong) Benefit ⋙ Risk (&Cost) Class IIa (Moderate) Benefit ≫ Risk (&Cost) Class IIb (Weak) Benefit ≥ Risk (&Cost) Class III: No Benefit (Moderate) Benefit = Risk (&Cost) Class III: Harm (Strong) Risk > Benefit (&Cost) The committee used a modified Delphi panel methodology, which employed an expert panel of clinicians who rated a series of anatomical scenarios with respect to COR/LOE. The panel participated in three rounds of voting, with communication among the panelists after the first anonymized round. Each panelist had equal weight in determining the final rating. Agreement among panelists was ac
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II)
Norgren, L., Hiatt, W. R., Dormandy, J. A., Nehler, M. R., Harris, K. A., & Fowkes, F. G. R. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.12.037 · Cited by 8,191
2016 AHA/ACC Guideline on the Management of Patients With Lower Extremity Peripheral Artery Disease
Gerhard-Herman, M. D., Gornik, H. L., Barrett, C., Barshes, N. R., Corriere, M. A., Drachman, D. E., Fleisher, L. A., Fowkes, F. G. R., Hamburg, N. M., Kinlay, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.007 · Cited by 1,941
Self-citationBalloon Angioplasty versus Implantation of Nitinol Stents in the Superficial Femoral Artery
Schillinger, M., Sabeti, S., Loewe, C., Dick, P., Amighi, J., Mlekusch, W., Schlager, O., Cejna, M., Lammer, J., & Minar, E. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa051303 · Cited by 1,157 · cited 2×
“, lesions >10 cm), data suggest superiority of bare metal stents over PTA with uncoated balloons alone [18,19].”
BackgroundTrial of a Paclitaxel-Coated Balloon for Femoropopliteal Artery Disease
Rosenfield, K., Jaff, M. R., White, C. J., Rocha-Singh, K., Mena-Hurtado, C., Metzger, D. C., Brodmann, M., Pilger, E., Zeller, T., Krishnan, P., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1406235 · Cited by 686
Self-citationTepe, G., Laird, J., Schneider, P., Brodmann, M., Krishnan, P., Micari, A., Metzger, C., Scheinert, D., Zeller, T., Cohen, D. J., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.011004 · Cited by 685
Self-citationLaird, J. R., Katzen, B. T., Scheinert, D., Lammer, J., Carpenter, J., Buchbinder, M., Dave, R., Ansel, G., Lansky, A., Cristea, E., et al. (2010) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.109.903468 · Cited by 627
Self-citationDake, M. D., Ansel, G. M., Jaff, M. R., Ohki, T., Saxon, R. R., Smouse, H. B., Zeller, T., Roubin, G. S., Burket, M. W., Khatib, Y., et al. (2011) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.111.962324 · Cited by 569 · cited 1×
“The Zilver PTX randomized trial enrolled 474 patients with claudication and SFA or proximal popliteal disease to DES or PTA [44].”
MethodSelf-citationDake, M. D., Ansel, G. M., Jaff, M. R., Ohki, T., Saxon, R. R., Smouse, H. B., Machan, L. S., Snyder, S. A., O’Leary, E. E., Ragheb, A. O., et al. (2016) · Circulation · doi:10.1161/circulationaha.115.016900 · Cited by 528
Self-citationKrankenberg, H., Schlüter, M., Steinkamp, H. J., Bürgelin, K., Scheinert, D., Schulte, K.-L., Minar, E., Peeters, P., Bosiers, M., Tepe, G., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.689141 · Cited by 516
Scheinert, D., Duda, S., Zeller, T., Krankenberg, H., Ricke, J., Bosiers, M., Tepe, G., Naisbitt, S., & Rosenfield, K. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.05.022 · Cited by 398 · cited 1×
“(Table 11) The LEVANT (Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis) 1 and 2 multicenter RCTs evaluated the Lutonix DCB with a dose of paclitaxel of 2 lg/mm(2), with a proprietary coating and polysorbate and sorbitol excipient [55,56].”
MethodSelf-citation
Cited by
Association of Survival With Femoropopliteal Artery Revascularization With Drug-Coated Devices
Secemsky, E. A., Kundi, H., Weinberg, I., Jaff, M. R., Krawisz, A., Parikh, S. A., Beckman, J. A., Mustapha, J., Rosenfield, K., & Yeh, R. W. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0325 · Cited by 211
Self-citation
Metadata
- Authors
- Feldman, D. N., Armstrong, E. J., Aronow, H. D., Gigliotti, O. S., Jaff, M. R., Klein, A. J., Parikh, S. A., Prasad, A., Rosenfield, K., Shishehbor, M. H., Swaminathan, R. V., & White, C. J.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2018-04-24
- Volume
- 92
- Issue
- 1
- Pages
- 124-140
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2802562571
- Cited by
- 171
- References
- 55
- FWCI
- 16.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.