Diagnostic accuracy of quantitative flow ratio for assessment of coronary stenosis significance from a single angiographic view: A novel method based on bifurcation fractal law
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Objectives: We aimed to evaluate the diagnostic accuracy of computation of fractional flow reserve (FFR) from a single angiographic view in patients with intermediate coronary stenosis. Background: Computation of quantitative flow ratio (QFR) from a single angiographic view might increase the feasibility of routine use of computational FFR. In addition, current QFR solutions assume a linear tapering of the reference vessel size, which might decrease the diagnostic accuracy in the presence of the physiologically significant bifurcation lesions. Methods: An artificial intelligence algorithm was proposed for automatic delineation of lumen contours of major epicardial coronary arteries including their side branches. A step‐down reference diameter function was reconstructed based on the Murray bifurcation fractal law and used for QFR computation. Validation of this Murray law‐based QFR (μQFR) was performed on the FAVOR II China study population. The μQFR was computed separately in two angiographic projections, starting with the one with optimal angiographic image quality. Hemodynamically significant coronary stenosis was defined by pressure wire‐derived FFR ≤0.80. Results: The μQFR was successfully computed in all 330 vessels of 306 patients. There was excellent correlation (r = 0.90, p < .001) and agreement (mean difference = 0.00 ± 0.05, p = .378) between μQFR and FFR. The vessel‐level diagnostic accuracy for μQFR to identify hemodynamically significant stenosis was 93.0% (95% CI: 90.3 to 95.8%), with sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of 87.5% (95% CI: 80.2 to 92.8%), 96.2% (95% CI: 92.6 to 98.3%), 92.9% (95% CI: 86.5 to 96.9%), 93.1% (95% CI: 88.9 to 96.1%), 23.0 (95% CI: 11.6 to 45.5), 0.13 (95% CI: 0.08 to 0.20), respectively. Use of suboptimal angiographic image view slightly decreased the diagnostic accuracy of μQFR (AUC = 0.97 versus 0.92, difference = 0.05, p < .001). Intra‐ and inter‐observer variability for μQFR computation was 0.00 ± 0.03, and 0.00 ± 0.03, respectively. Average analysis time for μQFR was 67 ± 22 s. Conclusions: Computation of μQFR from a single angiographic view has high feasibility and excellent diagnostic accuracy in identifying hemodynamically significant coronary stenosis. The short analysis time and good reproducibility of μQFR bear potential of wider adoption of physiological assessment in the catheterization laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes
Knuuti, J., Wijns, W., Saraste, A., Capodanno, D., Barbato, E., Funck-Brentano, C., Prescott, E., Storey, R. F., Deaton, C., Cuisset, T., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz425 · Cited by 7,166
Self-citationThe Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087
Tu, S., Westra, J., Yang, J., von Birgelen, C., Ferrara, A., Pellicano, M., Nef, H., Tebaldi, M., Murasato, Y., Lansky, A., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.013 · Cited by 591 · cited 1×
“Among them, quantitative flow ratio (QFR) is a novel approach for fast computation of FFR based on two angiographic views.(4,8) QFR has been validated extensively showing superior diagnostic metrics(9,10) and prognostic value.”
MethodSelf-citationKnuuti, J. (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-2-3757 · Cited by 396
The Evolving Future of Instantaneous Wave-Free Ratio and Fractional Flow Reserve
Götberg, M., Cook, C., Sen, S., Nijjer, S. S., Escaned, J., & Davies, J. E. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.770 · Cited by 216 · cited 1×
“Despite that the use of FFR for identifying flow limiting coronary stenosis has been recommended by major guidelines,(1) the clinical adaption of FFR remains low in many countries.(2) Several underlying reasons might explain this gap.”
MethodPrognostic Value of QFR Measured Immediately After Successful Stent Implantation
Biscaglia, S., Tebaldi, M., Brugaletta, S., Cerrato, E., Erriquez, A., Passarini, G., Ielasi, A., Spitaleri, G., Di Girolamo, D., Mezzapelle, G., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.06.003 · Cited by 177 · cited 2×
“The same limitation was found in studies investigating the feasibility of QFR computation in post-PCI settings.(11) Computation of μQFR based on a single angiographic view can resolve such a limitation, especially in patients with tortuous, sequential,”
BackgroundMethodCollet, C., Onuma, Y., Sonck, J., Asano, T., Vandeloo, B., Kornowski, R., Tu, S., Westra, J., Holm, N. R., Xu, B., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy445 · Cited by 165
Self-citationMasdjedi, K., van Zandvoort, L. J. C., Balbi, M. M., Gijsen, F. J. H., Ligthart, J. M. R., Rutten, M. C. M., Lemmert, M. E., Wilschut, J., Diletti, R., de Jaegere, P. P. T., et al. (2020) · EuroIntervention · doi:10.4244/eij-d-19-00466 · Cited by 155
Evolving Routine Standards in Invasive Hemodynamic Assessment of Coronary Stenosis
Tebaldi, M., Biscaglia, S., Fineschi, M., Musumeci, G., Marchese, A., Leone, A. M., Rossi, M. L., Stefanini, G. G., Maione, A., Menozzi, A., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.04.037 · Cited by 146 · cited 1×
“In addition to the cost of disposable pressure wire and the discomfort caused by hyperemia, it was reported that a major obstacle to the adoption of coronary physiological assessment in the catheterization laboratory lies in physician's confidence in visual assessment of angiographic images alone.(3) Thus, image-based…”
Background
Cited by
Xu, B., Tu, S., Song, L., Jin, Z., Yu, B., Fu, G., Zhou, Y., Wang, J., Chen, Y., Pu, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)02248-0 · Cited by 421
Self-citation
Metadata
- Authors
- Tu, S., Ding, D., Chang, Y., Li, C., Wijns, W., & Xu, B.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2021-03-04
- Volume
- 97
- Issue
- S2
- Pages
- 1040-1047
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W3135721060
- Cited by
- 206
- References
- 14
- FWCI
- 28.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.