Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 165

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnostic performance of angiography-derived fractional flow reserve: a systematic review and Bayesian meta-analysis

Open access
Collet, Carlos, Onuma, Yoshinobu, Sonck, Jeroen, Asano, Taku, Vandeloo, Bert, Kornowski, Ran, Tu, Shengxian, Westra, Jelmer, Holm, Niels R, Xu, Bo, de Winter, Robbert J, Tijssen, Jan G, Miyazaki, Yosuke, Katagiri, Yuki, Tenekecioglu, Erhan, Modolo, Rodrigo, Chichareon, Ply, Cosyns, Bernard, Schoors, Daniel, Roosens, Bram, Lochy, Stijn, Argacha, Jean-Francois, van Rosendael, Alexandre, Bax, Jeroen, Reiber, Johan H C, Escaned, Javier, De Bruyne, Bernard, Wijns, William, Serruys, Patrick W · 2018 · European Heart Journal

Abstract

Aims: Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. Methods and results: A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. Conclusion: The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehy445

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 165

Metadata

Authors
Collet, C., Onuma, Y., Sonck, J., Asano, T., Vandeloo, B., Kornowski, R., Tu, S., Westra, J., Holm, N. R., Xu, B., de Winter, R. J., Tijssen, J. G., Miyazaki, Y., Katagiri, Y., Tenekecioglu, E., Modolo, R., Chichareon, P., Cosyns, B., Schoors, D., Roosens, B., Lochy, S., Argacha, J.-F., van Rosendael, A., Bax, J., Reiber, J. H. C., Escaned, J., De Bruyne, B., Wijns, W., & Serruys, P. W.
Venue
European Heart Journal
Published
2018-08-20
Volume
39
Issue
35
Pages
3314-3321
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2888716150
Cited by
165
References
1
FWCI
4.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic performance of angiography-derived fractional flow reserve: a systematic review and Bayesian meta-analysis. https://app.cochat.ai/papers/10.1093/eurheartj/ehy445
The paper
Collet, C., Onuma, Y., Sonck, J., Asano, T., Vandeloo, B., Kornowski, R., Tu, S., Westra, J., Holm, N. R., Xu, B., de Winter, R. J., Tijssen, J. G., Miyazaki, Y., Katagiri, Y., Tenekecioglu, E., Modolo, R., Chichareon, P., Cosyns, B., Schoors, D., . . . Serruys, P. W. (2018). Diagnostic performance of angiography-derived fractional flow reserve: a systematic review and Bayesian meta-analysis. European Heart Journal. https://doi.org/10.1093/eurheartj/ehy445

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.