Self‐Charging Electrochemical Biocapacitor
The DOI matches its Crossref record.
Abstract
Two-in-one: A biological supercapacitor—a combination of an electrochemical capacitor and an enzymatic fuel cell—is presented. Both the capacitor and the biofuel cell are built from nanomaterials, namely, polyaniline/carbon nanotube composites and redox enzyme/gold nanoparticle assemblies. The biosupercapacitor is self-charging, membrane- and mediator-less.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Grattieri, M., & Minteer, S. D. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00818 · Cited by 312
Piezoelectric-Driven Self-Charging Supercapacitor Power Cell
Ramadoss, A., Saravanakumar, B., Lee, S. W., Kim, Y.-S., Kim, S. J., & Wang, Z. L. (2015) · ACS Nano · doi:10.1021/acsnano.5b00759 · Cited by 289
Progress in supercapacitors: roles of two dimensional nanotubular materials
Panda, P. K., Grigoriev, A., Mishra, Y. K., & Ahuja, R. (2020) · Nanoscale Advances · doi:10.1039/c9na00307j · Cited by 240
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
Self-citationNature‐Inspired Electrochemical Energy‐Storage Materials and Devices
Wang, H., Yang, Y., & Guo, L. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201601709 · Cited by 189
Stretchable and Flexible Buckypaper‐Based Lactate Biofuel Cell for Wearable Electronics
Chen, X., Yin, L., Lv, J., Gross, A. J., Le, M., Gutierrez, N. G., Li, Y., Jeerapan, I., Giroud, F., Berezovska, A., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201905785 · Cited by 188
Cholesterol Self-Powered Biosensor
Sekretaryova, A. N., Beni, V., Eriksson, M., Karyakin, A. A., Turner, A. P. F., & Vagin, M. Y. (2014) · Analytical Chemistry · doi:10.1021/ac501699p · Cited by 174
Ramanavicius, S., & Ramanavicius, A. (2021) · Nanomaterials · doi:10.3390/nano11020371 · Cited by 160
Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135
Self-citation
Metadata
- Authors
- Pankratov, D., Blum, Z., Suyatin, D. B., Popov, V. O., & Shleev, S.
- Venue
- ChemElectroChem
- Publisher
- Wiley
- Published
- 2013-12-11
- Volume
- 1
- Issue
- 2
- Pages
- 343-346
- ISSN
- 2196-0216 (ISSN-L)
- OpenAlex
- W2160261981
- Cited by
- 98
- References
- 0
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.