The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Electrochemical Biosensors in Point‐of‐Care Devices: Recent Advances and Future Trends
Abstract
The use of biosensors in point‐of‐care (POC) testing devices has attracted considerable attention in the past few years, mainly because of their high specificity, portability, and relatively low cost. Coupling these devices with miniaturized electrochemical transducers has shown great potential toward simple, rapid, and cost‐effective analysis that can be performed in the field, especially for healthcare, environmental monitoring, and food quality control. For this reason, the number of publications in this field has grown exponentially over the past decade, making it a trending topic in current research. Although great improvement has been achieved in the field of electrochemical biosensing, there are still some challenges to overcome, especially concerning the improvement of sensing materials and miniaturization. In this Review, we summarize some of the most recent advances achieved in POC electrochemical biosensor applications, focusing on new materials and modifiers for biorecognition developed to improve sensitivity, specificity, stability, and response time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Georgakilas, V., Tiwari, J. N., Kemp, K. C., Perman, J. A., Bourlinos, A. B., Kim, K. S., & Zboril, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00620 · Cited by 2,494
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Functional π-Gelators and Their Applications
Babu, S. S., Praveen, V. K., & Ajayaghosh, A. (2014) · Chemical Reviews · doi:10.1021/cr400195e · Cited by 1,725
Metadata
- Authors
- da Silva, E. T. S. G., Souto, D. E. P., Barragan, J. T. C., de F. Giarola, J., de Moraes, A. C. M., & Kubota, L. T.
- Venue
- ChemElectroChem
- Publisher
- Wiley
- Published
- 2017-02-08
- Volume
- 4
- Issue
- 4
- Pages
- 778-794
- ISSN
- 2196-0216 (ISSN-L)
- OpenAlex
- W2569176550
- Cited by
- 373
- References
- 88
- FWCI
- 10.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Biosensors in Point‐of‐Care Devices: Recent Advances and Future Trends. https://app.cochat.ai/papers/10.1002/celc.201600758
- The paper
- da Silva, E. T. S. G., Souto, D. E. P., Barragan, J. T. C., de F. Giarola, J., de Moraes, A. C. M., & Kubota, L. T. (2017). Electrochemical Biosensors in Point‐of‐Care Devices: Recent Advances and Future Trends. ChemElectroChem. https://doi.org/10.1002/celc.201600758
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.