The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Preprocessing methods for near‐infrared spectrum calibration
Abstract
Spectrum preprocessing is an essential component in the near‐infrared (NIR) calibration. However, it has mostly been configured arbitrarily in the literature and calibration applications. In this paper, a systematic evaluation framework was proposed to quantify the effect of preprocessing, where repeated cross‐validation and evaluation are involved. As many as 108 preprocessing schemes were gathered from the literature and were tested on 26 different NIR calibration problems. Using the evaluation framework, appropriate schemes can be found for several datasets, reducing the root mean square error of prediction (RMSEP) by 50%–60% compared with using the raw spectrum. However, the influence of preprocessing is highly data‐dependent, and no universal solution could be found. Taking the effectiveness and correlation into consideration, Savitzky‐Golay (SG), SG1D, and SG1D + vector normalization (VN)(/standard normal variate [SNV]) are worth testing first. Nevertheless, the heterogeneity at both the dataset level and sample level demonstrated the necessity of a complete evaluation. Our scripts are available at https://github.com/jiaoyiping630/spectrum-preprocessing .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Martens, H., & Stark, E. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80188-f · Cited by 515
Cited by
A Review of Machine Learning for Near-Infrared Spectroscopy
Zhang, W., Kasun, L. C., Wang, Q. J., Zheng, Y., & Lin, Z. (2022) · Sensors · doi:10.3390/s22249764 · Cited by 280
Metadata
- Authors
- Jiao, Y., Li, Z., Chen, X., & Fei, S.
- Venue
- Journal of Chemometrics
- Publisher
- Wiley
- Published
- 2020-10-15
- Volume
- 34
- Issue
- 11
- ISSN
- 0886-9383 (ISSN-L)
- 1099-128X
- OpenAlex
- W3092718721
- Cited by
- 198
- References
- 1
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.