Cited by 515Spectroscopy and Chemometric AnalysesSpectroscopy Techniques in Biomedical and Chemical ResearchOptical Imaging and Spectroscopy Techniques

Extended multiplicative signal correction and spectral interference subtraction: New preprocessing methods for near infrared spectroscopy

Martens, Harald, Stark, Edward·1991·Journal of Pharmaceutical and Biomedical Analysis

Abstract

Near infrared (NIR) spectroscopy spectra can be converted mathematically to precise quantitative information of chemical and physical nature by multivariate calibration. This makes NIR analysis useful for a variety of "difficult" sample types (powders, slurries), more or less without any sample preparation. The paper emphasizes the importance of using prior knowledge for spectral preprocessing of spectral data prior to the linear multivariate calibration modelling. Two new preprocessing methods are presented: extended multiplicative signal correction (EMSC) for elimination of uncontrollable path length or scattering effects, and spectral interference subtraction (SIS) for elimination of known spectral interferences. Determination of toluene in mixtures with benzene and xylene from NIR spectra with gross simulated light scattering effects is used for illustration.

Integrity signals

Registry

Crossref · 10.1016/0731-7085(91)80188-f

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The faint and/or overlapping overtone bands created from fundamental MIR bands, spectral interferences of water, and overall dynamic nature of bioreactions make on-line chemometric calibration models of NIR spectra complex.

    “This is because the faint and/or overlapping overtone bands created from fundamental MIR bands, spectral interferences of water [51], and overall dynamic nature of bioreactions.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Martens, H., & Stark, E.
Corresponding author
Martens, Harald
Venue
Journal of Pharmaceutical and Biomedical Analysis
Publisher
Elsevier BV
Published
1991-01
Volume
9
Issue
8
Pages
625-635
ISSN
0731-7085 (ISSN-L)
OpenAlex
W2058075292
Cited by
515
References
3
Citations by year
2026: 24 · 2025: 29 · 2024: 26 · 2023: 26 · 2022: 41 · 2021: 39 · 2020: 46 · 2019: 25 · 2018: 26 · 2017: 20 · 2016: 16 · 2015: 24 · 2014: 21 · 2013: 19 · 2012: 16
FWCI
3.01
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Pharmaceutical and Biomedical Analysis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
spectral preprocessing, near-infrared spectroscopy, light scattering correction, path length correction, multivariate calibration
MeSH terms
Calibration, Data Interpretation, Statistical, Fiber Optic Technology, Models, Chemical, Spectrophotometry, Infrared, Spectrum Analysis, Subtraction Technique, Multivariate Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review