The DOI matches its Crossref record.
A Ratiometric Fluorescent Probe for Hypochlorite Based on a Deoximation Reaction
Abstract
The first ratiometric fluorescent probe for hypochlorite has been developed through regulation of the electron‐withdrawing ability of the electron acceptor in an intramolecular charge‐transfer (ICT) system by a deoximation reaction (see figure; EWG=electron‐withdrawing group).magnified image In this work, we have successfully provided a novel strategy for the rational design and synthesis of a ratiometric fluorescent probe for hypochlorite. The strategy is based on the deoximation reaction, which has not yet been used in the fluorescent hypochlorite probe design. Interestingly, the probe showed a ratiometric fluorescent response to hypochlorite with the emission intensities ratio (I509/I439) increasing from 0.28 to 2.74. Furthermore, the probe displayed high selectivity for hypochlorite over other species due to the distinct deoximation conditions. The probe developed herein represents the first ratiometric fluorescent probe for hypochlorite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Du, J., Hu, M., Fan, J., & Peng, X. (2012) · Chemical Society Reviews · doi:10.1039/c2cs00004k · Cited by 688
Koide, Y., Urano, Y., Hanaoka, K., Terai, T., & Nagano, T. (2011) · Journal of the American Chemical Society · doi:10.1021/ja111470n · Cited by 576
Metadata
- Authors
- Lin, W., Long, L., Chen, B., & Tan, W.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2009-02-12
- Volume
- 15
- Issue
- 10
- Pages
- 2305-2309
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2009522492
- Cited by
- 264
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Ratiometric Fluorescent Probe for Hypochlorite Based on a Deoximation Reaction. https://app.cochat.ai/papers/10.1002/chem.200802054
- The paper
- Lin, W., Long, L., Chen, B., & Tan, W. (2009). A Ratiometric Fluorescent Probe for Hypochlorite Based on a Deoximation Reaction. Chemistry – A European Journal. https://doi.org/10.1002/chem.200802054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.