The DOI matches its Crossref record.
Fluorescent Bioprobes: Structural Matching in the Docking Processes of Aggregation‐Induced Emission Fluorogens on DNA Surfaces
Abstract
Whereas most conventional DNA probes are flat disklike aromatic molecules, we explored the possibility of developing quadruplex sensors with nonplanar conformations, in particular, the propeller‐shaped tetraphenylethene (TPE) salts with aggregation‐induced emission (AIE) characteristics. 1,1,2,2‐Tetrakis[4‐(2‐triethylammonioethoxy)phenyl]ethene tetrabromide (TPE‐1) was found to show a specific affinity to a particular quadruplex structure formed by a human telomeric DNA strand in the presence of K+ ions, as indicated by the enhanced and bathochromically shifted emission of the AIE fluorogen. Steady‐state and time‐resolved spectral analyses revealed that the specific binding stems from a structural matching between the AIE fluorogen and the DNA strand in the folding process. Computational modeling suggests that the AIE molecule docks on the grooves of the quadruplex surface with the aid of electrostatic attraction. The binding preference of TPE‐1 enables it to serve as a bioprobe for direct monitoring of cation‐driven conformational transitions between the quadruplexes of various conformations, a job unachievable by the traditional G‐quadruplex biosensors. Methyl thiazolyl tetrazolium (MTT) assays reveal that TPE‐1 is cytocompatible, posing no toxicity to living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationHong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Self-citationNew sensing mechanisms for design of fluorescent chemosensors emerging in recent years
Wu, J., Liu, W., Ge, J., Zhang, H., & Wang, P. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00224k · Cited by 1,858
Bioprobes Based on AIE Fluorogens
Ding, D., Li, K., Liu, B., & Tang, B. Z. (2013) · Accounts of Chemical Research · doi:10.1021/ar3003464 · Cited by 1,817
Self-citationBiosensing by luminogens with aggregation-induced emission characteristics
Kwok, R. T. K., Leung, C. W. T., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00325j · Cited by 1,296
Self-citationChromogenic/Fluorogenic Ensemble Chemosensing Systems
Wu, J., Kwon, B., Liu, W., Anslyn, E. V., Wang, P., & Kim, J. S. (2015) · Chemical Reviews · doi:10.1021/cr500553d · Cited by 402
Aggregation-Induced Emission: A Trailblazing Journey to the Field of Biomedicine
Zhu, C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2018) · ACS Applied Bio Materials · doi:10.1021/acsabm.8b00600 · Cited by 343
Self-citationAIE-based luminescence probes for metal ion detection
Alam, P., Leung, N. L. C., Zhang, J., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213693 · Cited by 275
Self-citationHuang, G., Ma, B., Chen, J., Peng, Q., Zhang, G., Fan, Q., & Zhang, D. (2012) · Chemistry – A European Journal · doi:10.1002/chem.201103675 · Cited by 78
Metadata
- Authors
- Hong, Y., Xiong, H., Lam, J. W. Y., Häußler, M., Liu, J., Yu, Y., Zhong, Y., Sung, H. H. Y., Williams, I. D., Wong, K. S., & Tang, B. Z.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2010-01-20
- Volume
- 16
- Issue
- 4
- Pages
- 1232-1245
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2126415275
- Cited by
- 178
- References
- 0
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.