The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Photoelectrochemical Immunosensor Based on Au‐Doped TiO2 Nanotube Arrays for the Detection of α‐Synuclein
Abstract
α‐Synuclein (α‐SYN) is a very important neuronal protein that is associated with Parkinson’s disease. In this paper, we utilized Au‐doped TiO 2 nanotube arrays to design a photoelectrochemical immunosensor for the detection of α‐SYN. The highly ordered TiO 2 nanotubes were fabricated by using an electrochemical anodization technique on pure Ti foil. After that, a photoelectrochemical deposition method was exploited to modify the resulting nanotubes with Au nanoparticles, which have been demonstrated to facilitate the improvement of photocurrent responses. Moreover, the Au‐doped TiO 2 nanotubes formed effective antibody immobilization arrays and immobilized primary antibodies (Ab 1) with high stability and bioactivity to bind target α‐SYN. The enhanced sensitivity was obtained by using {Ab 2‐Au‐GOx} bioconjugates, which featured secondary antibody (Ab 2) and glucose oxidase (GOx) labels linked to Au nanoparticles for signal amplification. The GOx enzyme immobilized on the prepared immunosensor could catalyze glucose in the detection solution to produce H 2 O 2, which acted as a sacrificial electron donor to scavenge the photogenerated holes in the valence band of TiO 2 nanotubes upon irradiation of the other side of the Ti foil and led to a prompt photocurrent. The photocurrents were proportional to the α‐SYN concentrations, and the linear range of the developed immunosensor was from 50 pg mL−1 to 100 ng mL−1 with a detection limit of 34 pg mL−1. The proposed method showed high sensitivity, stability, reproducibility, and could become a promising technique for protein detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stoscheck, C. M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82008-p · Cited by 1,438
Cited by
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Self-citationTitanium Dioxide Nanomaterials for Sensor Applications
Bai, J., & Zhou, B. (2014) · Chemical Reviews · doi:10.1021/cr400625j · Cited by 900
Photoelectrochemical DNA Biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr500100j · Cited by 857
Self-citationXue, J., Ma, S., Zhou, Y., Zhang, Z., & He, M. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b01212 · Cited by 667
Functionalized TiO2 Based Nanomaterials for Biomedical Applications
Wu, S., Weng, Z., Liu, X., Yeung, K. W. K., & Chu, P. K. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400706 · Cited by 269
Metadata
- Authors
- An, Y., Tang, L., Jiang, X., Chen, H., Yang, M., Jin, L., Zhang, S., Wang, C., & Zhang, W.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2010-10-29
- Volume
- 16
- Issue
- 48
- Pages
- 14439-14446
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2143365286
- Cited by
- 211
- References
- 1
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Photoelectrochemical Immunosensor Based on Au‐Doped TiO2 Nanotube Arrays for the Detection of α‐Synuclein. https://app.cochat.ai/papers/10.1002/chem.201001654
- The paper
- An, Y., Tang, L., Jiang, X., Chen, H., Yang, M., Jin, L., Zhang, S., Wang, C., & Zhang, W. (2010). A Photoelectrochemical Immunosensor Based on Au‐Doped TiO2 Nanotube Arrays for the Detection of α‐Synuclein. Chemistry – A European Journal. https://doi.org/10.1002/chem.201001654
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.