Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Photoelectrochemical Immunosensor Based on Au‐Doped TiO2 Nanotube Arrays for the Detection of α‐Synuclein

An, Yarui, Tang, Linlin, Jiang, Xiaoli, Chen, Hua, Yang, Meicheng, Jin, Litong, Zhang, Shengping, Wang, Chuangui, Zhang, Wen·2010·Chemistry – A European Journal

Abstract

α‐Synuclein (α‐SYN) is a very important neuronal protein that is associated with Parkinson’s disease. In this paper, we utilized Au‐doped TiO 2 nanotube arrays to design a photoelectrochemical immunosensor for the detection of α‐SYN. The highly ordered TiO 2 nanotubes were fabricated by using an electrochemical anodization technique on pure Ti foil. After that, a photoelectrochemical deposition method was exploited to modify the resulting nanotubes with Au nanoparticles, which have been demonstrated to facilitate the improvement of photocurrent responses. Moreover, the Au‐doped TiO 2 nanotubes formed effective antibody immobilization arrays and immobilized primary antibodies (Ab 1) with high stability and bioactivity to bind target α‐SYN. The enhanced sensitivity was obtained by using {Ab 2‐Au‐GOx} bioconjugates, which featured secondary antibody (Ab 2) and glucose oxidase (GOx) labels linked to Au nanoparticles for signal amplification. The GOx enzyme immobilized on the prepared immunosensor could catalyze glucose in the detection solution to produce H 2 O 2, which acted as a sacrificial electron donor to scavenge the photogenerated holes in the valence band of TiO 2 nanotubes upon irradiation of the other side of the Ti foil and led to a prompt photocurrent. The photocurrents were proportional to the α‐SYN concentrations, and the linear range of the developed immunosensor was from 50 pg mL−1 to 100 ng mL−1 with a detection limit of 34 pg mL−1. The proposed method showed high sensitivity, stability, reproducibility, and could become a promising technique for protein detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/chem.201001654

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 211

Metadata

Authors
An, Y., Tang, L., Jiang, X., Chen, H., Yang, M., Jin, L., Zhang, S., Wang, C., & Zhang, W.
Venue
Chemistry – A European Journal
Publisher
Wiley
Published
2010-10-29
Volume
16
Issue
48
Pages
14439-14446
ISSN
  • 0947-6539 (ISSN-L)
  • 1521-3765
OpenAlex
W2143365286
Cited by
211
References
1
FWCI
8.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Photoelectrochemical Immunosensor Based on Au‐Doped TiO2 Nanotube Arrays for the Detection of α‐Synuclein. https://app.cochat.ai/papers/10.1002/chem.201001654
The paper
An, Y., Tang, L., Jiang, X., Chen, H., Yang, M., Jin, L., Zhang, S., Wang, C., & Zhang, W. (2010). A Photoelectrochemical Immunosensor Based on Au‐Doped TiO2 Nanotube Arrays for the Detection of α‐Synuclein. Chemistry – A European Journal. https://doi.org/10.1002/chem.201001654

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.