The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fluorescent Detection of Hypochlorous Acid from Turn‐On to FRET‐Based Ratiometry by a HOCl‐Mediated Cyclization Reaction
Abstract
Hypochlorous acid (HOCl), a reactive oxygen species (ROS), plays a significant biological role in living systems. However, abnormal levels of HOCl are implicated in many inflammation‐associated diseases. Therefore, the detection of HOCl is of great importance. In this work, we describe the HOCl‐promoted cyclization of rhodamine‐thiosemicarbazides to rhodamine‐oxadiazoles, which is then exploited as a novel design strategy for the development of a new fluorescence turn‐on HOCl probe 2. On the basis of the fluorescence resonance energy transfer (FRET) signaling mechanism, 2 was further converted into 1 a and 1 b, which represent the first paradigm of FRET‐based ratiometric fluorescent HOCl probes. The outstanding features of 1 a and 1 b include well‐resolved emission peaks, high sensitivity, high selectivity, good functionality at physiological pH, rapid response, low cytotoxicity, and good cell‐membrane permeability. Furthermore, these excellent attributes enable us to demonstrate, for the first time, the ratiometric imaging of endogenously produced HOCl in living cells by using these novel ratiometric probes. We expect that 1 a and 1 b will be useful molecular tools for studies of HOCl biology. In addition, the HOCl‐promoted cyclization reaction of rhodamine‐thiosemicarbazides to rhodamine‐oxadiazoles should be widely applicable for the development of different types of fluorescent HOCl probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daugherty, A., Dunn, J. L., Rateri, D. L., & Heinecke, J. W. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117342 · Cited by 1,269
Albrich, J. M., McCarthy, C. A., & Hurst, J. K. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.1.210 · Cited by 442
Cited by
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Yuan, L., Wang, L., Agrawalla, B. K., Park, S.-J., Zhu, H., Sivaraman, B., Peng, J., Xu, Q.-H., & Chang, Y.-T. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b00042 · Cited by 558
Self-citationZhu, H., Fan, J., Wang, J., Mu, H., & Peng, X. (2014) · Journal of the American Chemical Society · doi:10.1021/ja505988g · Cited by 516
Xu, J., Pan, J., Jiang, X., Qin, C., Zeng, L., Zhang, H., & Zhang, J. F. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.049 · Cited by 278
Recent progress in the development of fluorescent probes for the detection of hypochlorous acid
Zhang, Y.-R., Liu, Y., Feng, X., & Zhao, B.-X. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.08.066 · Cited by 264
Metadata
- Authors
- Yuan, L., Lin, W., Xie, Y., Chen, B., & Song, J.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2012-01-23
- Volume
- 18
- Issue
- 9
- Pages
- 2700-2706
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2100056598
- Cited by
- 181
- References
- 2
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent Detection of Hypochlorous Acid from Turn‐On to FRET‐Based Ratiometry by a HOCl‐Mediated Cyclization Reaction. https://app.cochat.ai/papers/10.1002/chem.201101918
- The paper
- Yuan, L., Lin, W., Xie, Y., Chen, B., & Song, J. (2012). Fluorescent Detection of Hypochlorous Acid from Turn‐On to FRET‐Based Ratiometry by a HOCl‐Mediated Cyclization Reaction. Chemistry – A European Journal. https://doi.org/10.1002/chem.201101918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.