Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Toxicity of Graphene Oxides: Dependence on the Oxidative Methods Used

Chng, Elaine Lay Khim, Pumera, Martin · 2013 · Chemistry – A European Journal

Abstract

Graphene, a class of two‐dimensional carbon nanomaterial, has attracted extensive interest in recent years, with a significant amount of research focusing on graphene oxides (GOs). They have been primed as potential candidates for biomedical applications such as cell labeling and drug delivery, thus the toxicity and behavior of graphene oxides in biological systems are fundamental issues that need urgent attention. The production of GO is generally achieved through a top‐down route, which includes the usage of concentrated H 2 SO 4 along with: 1) concentrated nitric acid and KClO 3 oxidant (Hoffmann); 2) fuming nitric acid and KClO 3 oxidant (Staudenmaier); 3) concentrated phosphoric acid with KMnO 4 (Tour); or 4) sodium nitrate for in‐situ production of nitric acid in the presence of KMnO 4 (Hummers). It has been widely assumed that the properties of these four GOs produced by using the above different methods are roughly similar, so the methods have been used interchangeably. However, several studies have reported that the toxicity of graphene‐related nanomaterials in biological systems may be influenced by their physiochemical properties, such as surface functional groups and structural defects. In addition, considering how GOs are increasingly used in the field of biomedicine, we are interested to see how the oxygen content/functional groups of GOs can impact their toxicological profiles. Since in‐vitro testing is a common first step in assessing the health risks related with engineered nanomaterials, the cytotoxicity of the GOs prepared by the four different oxidative treatments was investigated by measuring the mitochondrial activity in adherent lung epithelial cells (A549) by using commercially available viability assays. The dose–response data was generated by using two assays, the methylthiazolyldiphenyl‐tetrazolium bromide (MTT) assay and the water‐soluble tetrazolium salt (WST‐8). From the viability data, it is evident that there is a strong dose‐dependent cytotoxic response resulting from the four GO nanomaterials tested after a 24 h exposure, and it is suggested that there is a correlation between the amounts of oxygen content/functional groups of GOs with their toxicological behavior towards the A549 cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/chem.201300824

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 162

Metadata

Authors
Chng, E. L. K., & Pumera, M.
Venue
Chemistry – A European Journal
Publisher
Wiley
Published
2013-04-29
Volume
19
Issue
25
Pages
8227-8235
ISSN
  • 0947-6539 (ISSN-L)
  • 1521-3765
OpenAlex
W2105578054
Cited by
162
References
2
FWCI
9.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Toxicity of Graphene Oxides: Dependence on the Oxidative Methods Used. https://app.cochat.ai/papers/10.1002/chem.201300824
The paper
Chng, E. L. K., & Pumera, M. (2013). The Toxicity of Graphene Oxides: Dependence on the Oxidative Methods Used. Chemistry – A European Journal. https://doi.org/10.1002/chem.201300824

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.