The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
The effect of particle size distribution on packing density
Abstract
The packing density of a multi‐particle system is found to increase if the particle size distribution is extended. Results are reported for Gaussian and log‐normal size distributions using dense random packing of two sands with particle sizes of front <0.07 to 8.0 mm. Packing density is shown to be a function only of size distribution represented by a dimensionless standard deviation, and of particle shape. It is independent of particle size. Packing densities of binary mixtures of continuously distributed systems are found to depend upon the composition of the mixture, the mean‐size ratio of the components of the binary, and upon the packing density of the individual components. Maxima occur at compositions of 55 to 75% larger component, and increasing mean‐size ratios result in greater packing densities. The “increase in packing density” factor is a useful function for comparing, and setting limits to, packing densities of binary mixtures. The results should allow improved prediction and control of packing densities of many commonly encountered particle systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volume, Shape, and Roundness of Quartz Particles
Wadell, H. (1935) · The Journal of Geology · doi:10.1086/624298 · Cited by 1,149
Mechanical Packing of Spherical Particles
McGEARY, R. K. (1961) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1961.tb13716.x · Cited by 1,044
Packing of Spheres: Packing of Equal Spheres
SCOTT, G. D. (1960) · Nature · doi:10.1038/188908a0 · Cited by 830
Some Studies on the Porosity and Permeability of Rocks
Tickell, F. G., Mechem, O. E., & McCurdy, R. C. (1933) · Transactions of the AIME · doi:10.2118/933250-g · Cited by 17
Cited by
Binder jet 3D printing—Process parameters, materials, properties, modeling, and challenges
Mostafaei, A., Elliott, A. M., Barnes, J. E., Li, F., Tan, W., Cramer, C. L., Nandwana, P., & Chmielus, M. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100707 · Cited by 1,093
Binder jetting: A review of process, materials, and methods
Ziaee, M., & Crane, N. B. (2019) · Additive Manufacturing · doi:10.1016/j.addma.2019.05.031 · Cited by 819
DULLIEN, F. A. L. (1992) · Porous Media · doi:10.1016/b978-0-12-223651-8.50007-9 · Cited by 458
A Review on Binder Jet Additive Manufacturing of 316L Stainless Steel
Mirzababaei, S., & Pasebani, S. (2019) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp3030082 · Cited by 290
3D inkjet printing of biomaterials: Principles and applications
Barui, S. (2021) · MEDICAL DEVICES & SENSORS · doi:10.1002/mds3.10143 · Cited by 48
Metadata
- Authors
- Sohn, H. Y., & Moreland, C.
- Venue
- The Canadian Journal of Chemical Engineering
- Publisher
- Wiley
- Published
- 1968-06
- Volume
- 46
- Issue
- 3
- Pages
- 162-167
- ISSN
- 0008-4034 (ISSN-L)
- 1939-019X
- OpenAlex
- W2121981416
- Cited by
- 298
- References
- 4
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.