Cost‐Effectiveness of Remote Cardiac Monitoring With the CardioMEMS Heart Failure System
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Heart failure (HF) is a leading cause of cardiovascular mortality in the United States and presents a substantial economic burden. A recently approved implantable wireless pulmonary artery pressure remote monitor, the CardioMEMS HF System, has been shown to be effective in reducing hospitalizations among New York Heart Association (NYHA) class III HF patients. The objective of this study was to estimate the cost‐effectiveness of this remote monitoring technology compared to standard of care treatment for HF. A Markov cohort model relying on the CHAMPION(CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) clinical trial for mortality and hospitalization data, published sources for cost data, and a mix of CHAMPION data and published sources for utility data, was developed. The model compares outcomes over 5 years for implanted vs standard of care patients, allowing patients to accrue costs and utilities while they remain alive. Sensitivity analyses explored uncertainty in input parameters. The CardioMEMS HF System was found to be cost‐effective, with an incremental cost‐effectiveness ratio of $44,832 per quality‐adjusted life year (QALY). Sensitivity analysis found the model was sensitive to the device cost and to whether mortality benefits were sustained, although there were no scenarios in which the cost/QALY exceeded $100,000. Compared with standard of care, the CardioMEMS HF System was cost‐effective when leveraging trial data to populate the model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Updating cost-effectiveness—the curious resilience of the $50,000-per-QALY threshold
Neumann, P. J., Cohen, J. T., & Weinstein, M. C. (2014) · New England Journal of Medicine · doi:10.1056/nejmp1405158 · Cited by 2,249 · cited 1×
“This finding puts CardioMEMS in the high-to-intermediate value according to the American College of Cardiology/American Heart Association(27) and other organizations.(30,31)”
MethodAbraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
Telemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232
Ong, M. K., Romano, P. S., Edgington, S., Aronow, H. U., Auerbach, A. D., Black, J. T., De Marco, T., Escarce, J. J., Evangelista, L. S., Hanna, B., et al. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.7712 · Cited by 695 · cited 1×
“Telemonitoring was not shown to reduce readmission rates significantly in 2 recent large studies.(10,11) Remote monitoring may be more beneficial for certain populations than others,(12) although few studies have examined this question in detail.”
BackgroundSelf-citationEddy, D. M., Hollingworth, W., Caro, J. J., Tsevat, J., McDonald, K. M., & Wong, J. B. (2012) · Value in Health · doi:10.1016/j.jval.2012.04.012 · Cited by 466
Inglis, S. C., Clark, R. A., McAlister, F. A., Stewart, S., & Cleland, J. G. F. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr039 · Cited by 378 · cited 1×
“However, recent published studies have started to explore the literature on remote monitoring to understand variation in success rates and the inconsistent definition of remote monitoring.(7,13,14) The effectiveness of remote monitoring may also depend on the particular monitoring device/system or patient characterist…”
BackgroundKitsiou, S., Paré, G., & Jaana, M. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4174 · Cited by 327 · cited 1×
“The effectiveness of remote monitoring may also depend on the particular monitoring device/system or patient characteristics.(15,16)”
BackgroundKarnon, J., Stahl, J., Brennan, A., Caro, J. J., Mar, J., & Möller, J. (2012) · Value in Health · doi:10.1016/j.jval.2012.04.013 · Cited by 240
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28 · cited 6×
“Second, the model incorporates a decrement in utilities to reflect what is known about the burden of hospitalization in HF.”
BackgroundInfluential
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Self-citation2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Self-citation2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure: Executive Summary
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.011 · Cited by 931
Self-citationA Survey of Healthcare Internet of Things (HIoT): A Clinical Perspective
Habibzadeh, H., Dinesh, K., Rajabi Shishvan, O., Boggio-Dandry, A., Sharma, G., & Soyata, T. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2946359 · Cited by 417
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001062 · Cited by 394
Self-citation
Metadata
- Authors
- Schmier, J. K., Ong, K. L., & Fonarow, G. C.
- Venue
- Clinical Cardiology
- Publisher
- Wiley
- Published
- 2017-03-08
- Volume
- 40
- Issue
- 7
- Pages
- 430-436
- ISSN
- 0160-9289 (ISSN-L)
- 1932-8737
- OpenAlex
- W2594707227
- Cited by
- 92
- References
- 10
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.