Remote monitoring of implantable devices: should we continue to ignore it?
Abstract
The number of patients with implantable cardioverter defibrillators (ICDs) is increasing. In addition to improve survival, ICD can collect data related to device function and physiological parameters. Remote monitoring (RM) of these data allows early detection of technical or clinical problems and a prompt intervention (reprogramming device or therapy adjustment) before the patient require hospitalization. RM is not a substitute for emergency service and its consultation is now limited during working hours. Thus, a consent form is required to inform patients about benefits and limitations. The available studies indicate that remote monitoring is more effective than traditional calendar face to face based encounters. RM is safe, highly reliable, cost efficient, allows quick reply to failures, and reduces the number of scheduled visits and the incidence of inappropriate shocks with a positive impact on survival. It follows that RM has the credentials to be the standard of care for ICD management; however, unfortunately, there is a delay in physician acceptance and implementation. The recent observations from randomized IN-TIME study that showed a clear survival benefit with RM in heart failure patients have encouraged us to review both the negative and positive aspects of RM collected in a little more than a decade.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In many countries, modern clinical management of ICD patients has moved from frequent outpatient follow-ups to more remote device monitoring, which may impede identification and support for the subset of patients struggling with device acceptance.
“In many countries, modern clinical management of ICD patients has moved from frequent outpatient follow-ups to more remote device monitoring,8 which may impede identification and support for the subset of patients struggling with device acceptance”
In the last decade, face-to-face outpatient visits for ICD patients have largely been replaced by remote monitoring, although variability exists between countries.
“In the last decade, we have witnessed a change in the management of ICD patients, with face-to-face outpatient visits largely being replaced by remote monitoring [20], although variability exists between countries.”
Cites
Rehospitalizations among Patients in the Medicare Fee-for-Service Program
Jencks, S. F., Williams, M. V., & Coleman, E. A. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0803563 · Cited by 5,164 · see citing works
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,495 · see citing works
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R., Marchlinski, F. E., Yee, R. K., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,458 · see citing works
Reduction in Inappropriate Therapy and Mortality through ICD Programming
Moss, A. J., Schuger, C. D., Beck, C. A., Brown, M. W., Cannom, D. S., Daubert, J. P., Estes, N. A. M., Greenberg, H., Hall, W. J., Huang, D. T.-C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1211107 · Cited by 1,369 · see citing works
Telemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232 · see citing works
Hindricks, G., Táborský, M., Glikson, M., Heinrich, U., Schumacher, B., Katz, A., Brachmann, J., Lewalter, T., Goette, A., Block, M. S., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61176-4 · Cited by 742 · see citing works
Koehler, F., Winkler, S., Schieber, M., Sechtem, U., Stangl, K., Böhm, M., Boll, H., Baumann, G., Honold, M., Koehler, K., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.018473 · Cited by 716 · see citing works
Kleemann, T., Becker, T., Doenges, K., Vater, M., Senges, J., Schneider, S., Saggau, W., Weisse, U., & Seidl, K. (2007) · Circulation · doi:10.1161/circulationaha.106.663807 · Cited by 633 · see citing works
Moss, A. J., Greenberg, H., Case, R. B., Zaręba, W., Hall, W. J., Brown, M. W., Daubert, J. P., McNitt, S. A., Andrews, M. L., & Elkin, A. D. (2004) · Circulation · doi:10.1161/01.cir.0000150390.04704.b7 · Cited by 599 · see citing works
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594 · see citing works
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526 · see citing works
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515 · see citing works
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 478 · see citing works
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467 · see citing works
van Veldhuisen, D. J., Braunschweig, F., Conraads, V. M., Ford, I., Cowie, M., Jondeau, G., Kautzner, J., Aguilera, R. M., Lunati, M., Yu, C., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.043042 · Cited by 443 · see citing works
Capucci, A., Santini, M., Padeletti, L., Gulizia, M. M., Botto, G., Boriani, G., Ricci, R. P., Favale, S., Zolezzi, F., Belardino, N. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 400 · see citing works
A Meta-Analysis of Remote Monitoring of Heart Failure Patients
Klersy, C., Silvestri, A. D., Gabutti, G., Regoli, F. D., & Auricchio, A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.017 · Cited by 379 · see citing works
Inglis, S. C., Clark, R. A., McAlister, F. A., Stewart, S., & Cleland, J. G. F. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr039 · Cited by 378 · see citing works
Whellan, D. J., Ousdigian, K. T., Al‐Khatib, S. M., Pu, W., Sarkar, S., Porter, C., Pavri, B. B., & O’Connor, C. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.089 · Cited by 373 · see citing works
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182618569 · Cited by 369 · see citing works
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364 · see citing works
A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)
Mabo, P., Victor, F., Bazin, P., Ahres, S., Babuty, D., Da Costa, A., Binet, D., & Daubert, J.-C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr419 · Cited by 347 · see citing works
Guédon-Moreau, L., Lacroix, D., Sadoul, N., Clémenty, J., Kouakam, C., Js, H., Aliot, E., Boursier, M., Bizeau, O., Kacet, S., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs425 · Cited by 307 · see citing works
Gould, P. A. (2006) · JAMA · doi:10.1001/jama.295.16.1907 · Cited by 284 · see citing works
Complications of Implantable Cardioverter Defibrillator Therapy in 440 Consecutive Patients
Alter, P. J., Waldhans, S., PLACHTA, E., Moosdorf, R., & Grimm, W. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00195.x · Cited by 273 · see citing works
Task Force Chairs, Daubert, J., Saxon, L. A., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J. G. F., et al. (2012) · EP Europace · doi:10.1093/europace/eus222 · Cited by 256 · see citing works
Lazarus, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00595.x · Cited by 227 · see citing works
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202 · see citing works
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
Burri, H., & Senouf, D. (2009) · EP Europace · doi:10.1093/europace/eup110 · Cited by 180 · see citing works
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P. E., Stone, P. H., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P. F., BREITHARDT, G. E., et al. (2012) · EP Europace · doi:10.1093/europace/eur303 · Cited by 178 · see citing works
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · EP Europace · doi:10.1093/europace/eun303 · Cited by 169 · see citing works
Automatic Remote Monitoring of Implantable Cardioverter-Defibrillator Lead and Generator Performance
Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. A. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.951962 · Cited by 164 · see citing works
Swerdlow, C. D., Gunderson, B. D., Ousdigian, K. T., Abeyratne, A., Stadler, R. W., Gillberg, J. M., Patel, A. S., & Ellenbogen, K. A. (2008) · Circulation · doi:10.1161/circulationaha.108.796136 · Cited by 141 · see citing works
Heidbuchel, H., Lioen, P., Foulon, S., Huybrechts, W., Ector, J., Willems, R., & Ector, H. (2008) · EP Europace · doi:10.1093/europace/eun010 · Cited by 132 · see citing works
Spencker, S., Coban, N., Koch, L., Schirdewan, A., & Muller, D. W. (2008) · EP Europace · doi:10.1093/europace/eun350 · Cited by 129 · see citing works
Hauser, R. G., McGriff, D. M., & Retel, L. K. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.019 · Cited by 124 · see citing works
Santini, M., Gasparini, M., Landolina, M., Lunati, M., Proclemer, A., Padeletti, L., Catanzariti, D., Molon, G., Botto, G. L., La Rocca, L., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.08.624 · Cited by 121 · see citing works
Detection of Atrial Fibrillation by Implanted Devices with Wireless Data Transmission Capability
Varma, N., Stambler, B. S., & Chun, S. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00083.x · Cited by 121 · see citing works
Heidbüchel, H., Hindricks, G., Broadhurst, P., van Erven, L., Lozano, I. F., Rivero‐Ayerza, M., MALINOWSKI, K., Marek, A., Garrido, R. R., Löscher, S., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu339 · Cited by 115 · see citing works
Boriani, G., Costa, A. D., Ricci, R. P., Quesada, A., Favale, S., Iacopino, S., Romeo, F., Risi, A., Stefano, L. M. D. S., Navarro, X., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2608 · Cited by 107 · see citing works
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102 · see citing works
Varma, N., Michalski, J., Stambler, B. S., Pavri, B. B., & TRUST Investigators (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu066 · Cited by 99 · see citing works
What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?
Brugada, P. (2006) · Clinical Research in Cardiology · doi:10.1007/s00392-006-1302-x · Cited by 94 · see citing works
Altman, R., Parks, K. A., Schlett, C. L., Orencole, M. P., Park, M.-Y., Truong, Q. A., Deeprasertkul, P., Moore, S. A., Barrett, C. D., Lewis, G. D., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs107 · Cited by 93 · see citing works
Guédon-Moreau, L., Chevalier, P., Marquié, C., Kouakam, C., Klug, D., Lacroix, D., Brigadeau, F., Kacet, S., & on behalf of the ECOST trial Investigators (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq203 · Cited by 68 · see citing works
Kallinen, L. M., Hauser, R. G., Tang, C., Melby, D. P., Almquist, A. K., Katsiyiannis, W. T., & Gornick, C. C. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.05.015 · Cited by 62 · see citing works
Hernández‐Madrid, A., Lewalter, T., Proclemer, A., Pison, L., Lip, G. Y. H., & Blomström‐Lundqvist, C. (2013) · EP Europace · doi:10.1093/europace/eut414 · Cited by 54 · see citing works
Complications Associated with Generator Replacement in Response to Device Advisories
Costea, A., Rardon, D. P., Padanilam, B. J., Fogel, R. I., & Prystowsky, E. N. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.01047.x · Cited by 54 · see citing works
Marinskis, G., van Erven, L., Bongiorni, M. G., Lip, G. Y. H., Pison, L., & Blomström‐Lundqvist, C. (2012) · EP Europace · doi:10.1093/europace/eus020 · Cited by 47 · see citing works
Krebsbach, A. L., Alhumaid, F., Henrikson, C. A., Calkins, H. G., Berger, R. D., & Cheng, A. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02042.x · Cited by 42 · see citing works
Compliance with Remote Monitoring of ICDS/CRTDS in a Real‐World Population
Rosenfeld, L. E., Patel, A. S., Ajmani, V. B., Holbrook, R., & BRAND, T. A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12358 · Cited by 40 · see citing works
VOGTMANN, T., Stiller, S., Marek, A., Kespohl, S., Gomer, M., Kühlkamp, V., Zach, G., Löscher, S., & Baumann, G. (2012) · EP Europace · doi:10.1093/europace/eus252 · Cited by 39 · see citing works
Morgan, J. M., Dimitrov, B. D., Gill, J., Kitt, S., Ng, G. A., McComb, J. M., Raftery, J. P., Roderick, P. J., Seed, A., Williams, S. G., et al. (2014) · European Journal of Heart Failure · doi:10.1002/ejhf.149 · Cited by 38 · see citing works
Abraham, W. T. (2013) · EP Europace · doi:10.1093/europace/eut105 · Cited by 38 · see citing works
Longitudinal Follow-Up of Implantable Cardioverter Defibrillator Leads
Liu, J., Brumberg, G. E., Rattan, R., Patel, D. R., ADELSTEIN, E. C., Jain, S. K., & Saba, S. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.08.046 · Cited by 36 · see citing works
Workflow, time and patient satisfaction from the perspectives of Home Monitoring
Ricci, R. P., & Morichelli, L. (2013) · EP Europace · doi:10.1093/europace/eut113 · Cited by 34 · see citing works
Disease management: atrial fibrillation and Home Monitoring
Ricci, R. P. (2013) · EP Europace · doi:10.1093/europace/eut114 · Cited by 26 · see citing works
Current clinical evidence for remote patient management
Guédon-Moreau, L., Mabo, P., & Kacet, S. (2013) · EP Europace · doi:10.1093/europace/eut119 · Cited by 25 · see citing works
Ricci, R. P., Calcagnini, G., Castro, A., Giada, F., Igidbashan, D., Landolina, M., Melissano, D., Perego, G. B., & Toselli, T. (2011) · Giornale italiano di cardiologia · doi:10.1714/835.9311 · Cited by 22 · see citing works
Self-citationComplications of replacing implantable devices in response to advisories: A single center experience
Moore, J. W., Barrington, W., Bazaz, R. R., Jain, S. K., Němec, J., Ngwu, O., Schwartzman, D. A., Shalaby, A. A., & Saba, S. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.12.070 · Cited by 19 · see citing works
Home Monitoring: what can we expect in the future?
Deharo, J., & DJIANE, P. (2006) · Clinical Research in Cardiology · doi:10.1007/s00392-006-1307-5 · Cited by 17 · see citing works
Automatic remote monitoring: milestones reached, paths to pave
Varma, N., & Brugada, P. (2013) · EP Europace · doi:10.1093/europace/eut118 · Cited by 10 · see citing works
Theuns, D. A. M. J., & Jordaens, L. J. L. M. (2011) · Netherlands Heart Journal · doi:10.1007/s12471-011-0228-8 · Cited by 7 · see citing works
Remote monitoring and the twin epidemics of atrial fibrillation and chronic heart failure
Santini, M. (2013) · EP Europace · doi:10.1093/europace/eut120 · Cited by 7 · see citing works
Marcantoni, L., Toselli, T., Urso, G., Pratola, C., Ceconi, C., & Bertini, M. (2014) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000148 · Cited by 7 · see citing works
Self-citationDierckx, R., Houben, R. P. M., Goethals, M. A., Verstreken, S., Bartúnek, J., Saeys, R., Proft, M. D., Boel, E., & Vanderheyden, M. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.01.088 · Cited by 3 · see citing works
Lewalter, T., & Brodherr, T. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu372 · Cited by 2 · see citing works
Flagged first, then by citations
1 of the 68 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Fog Computing in Healthcare–A Review and Discussion
Kraemer, F. A., Bråten, A. E., Tamkittikhun, N., & Palma, D. (2017) · IEEE Access · doi:10.1109/access.2017.2704100 · Cited by 335 · see citing works
Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D. S. S., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 228 · see citing works
Fog Computing Service in the Healthcare Monitoring System for Managing the Real-Time Notification
Elhadad, A., Alanazi, F., Taloba, A. I., & Abozeid, A. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/5337733 · Cited by 97 · see citing works
Cost‐Effectiveness of Remote Cardiac Monitoring With the CardioMEMS Heart Failure System
Schmier, J. K., Ong, K. L., & Fonarow, G. C. (2017) · Clinical Cardiology · doi:10.1002/clc.22696 · Cited by 92 · see citing works
Mani, N., Singh, A. K., & Nimmagadda, S. L. (2020) · Procedia Computer Science · doi:10.1016/j.procs.2020.03.424 · Cited by 74 · see citing works
Pedersen, S. S., Knudsen, C., Dilling, K., Sandgaard, N. C. F., & Johansen, J. B. (2016) · Europace · doi:10.1093/europace/euw109 · Cited by 43 · see citing works
Liljeroos, M., Thylén, I., & Strömberg, A. (2020) · Journal of Medical Internet Research · doi:10.2196/19550 · Cited by 42 · see citing works
Heart failure: an historical perspective
Ferrari, R., Balla, C., & Fucili, A. (2016) · European Heart Journal Supplements · doi:10.1093/eurheartj/suw042 · Cited by 39 · see citing works
Self-citationBraunschweig, F., Anker, S. D., Proff, J., & Varma, N. (2019) · EP Europace · doi:10.1093/europace/euz011 · Cited by 31 · see citing works
Hansen, C., Loges, C., Seidl, K., Eberhardt, F., Tröster, H., Petrov, K., Grönefeld, G., Bramlage, P., Birkenhauer, F., & Weiß, C. H. (2018) · BMC Cardiovascular Disorders · doi:10.1186/s12872-018-0864-7 · Cited by 21 · see citing works
Ono, M., & Varma, N. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1306438 · Cited by 19 · see citing works
IoT services in healthcare industry with fog/edge and cloud computing
Kumar, D., Maurya, A. K., & Baranwal, G. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821472-5.00017-x · Cited by 19 · see citing works
Pedersen, S. S., Skovbakke, S. J., Wiil, U. K., Schmidt, T., dePont Christensen, R., Brandt, C. J., Sørensen, J., Vinther, M., Larroudé, C. E., Melchior, T. M., et al. (2018) · BMC Cardiovascular Disorders · doi:10.1186/s12872-018-0872-7 · Cited by 18 · see citing works
Fog Computing Architectures and Frameworks for Healthcare 4.0
Nair, A. R., & Tanwar, S. (2020) · Signals and communication technology · doi:10.1007/978-3-030-46197-3_3 · Cited by 14 · see citing works
Towards Reliable Remote Health Monitoring in Fog Computing Networks
Dieye, M., Mseddi, A., Jaafar, W., & Elbiaze, H. (2022) · IEEE Transactions on Network and Service Management · doi:10.1109/tnsm.2022.3194806 · Cited by 12 · see citing works
Skov, O., Johansen, J. B., Nielsen, J. C., Larroudé, C. E., Riahi, S., Melchior, T. M., Vinther, M., Skovbakke, S. J., Rottmann, N., Wiil, U. K., et al. (2023) · Europace · doi:10.1093/europace/euad253 · Cited by 10 · see citing works
“7 In many countries, modern clinical management of ICD patients has moved from frequent outpatient follow-ups to more remote device monitoring, 8 which may impede identification and support for the subset of patients struggling with device acceptance defined as ‘the psychological accommodation and…”
BackgroundRemote Monitoring for Chronic Disease Management
Ono, M., & Varma, N. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2017.11.005 · Cited by 10 · see citing works
Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
Reinhardt, A., & Ventura, R. (2023) · Current Heart Failure Reports · doi:10.1007/s11897-023-00586-1 · Cited by 8 · see citing works
Leveraging Fog Computing for Healthcare
Katal, A. (2023) · Advanced technologies and societal change · doi:10.1007/978-981-19-5723-9_4 · Cited by 6 · see citing works
Nagy, B., Pál-Jakab, Á., Kiss, B., Orbán, G., Torda, L. S., Dabasi-Halász, Z., Móka, B. B., Gellér, L., Merkely, B. P., & Zima, E. (2023) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd10050214 · Cited by 5 · see citing works
Use of remote monitoring in the management of ICD end-of-life: Data from the DECODE registry
Campana, A., Giofrè, F., Stabile, G., Iori, M., Rosa, C. L., Tomasi, C., Calzolari, V., Miracapillo, G., Notarstefano, P., Carinci, V., et al. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.07.012 · Cited by 5 · see citing works
Explainable AI models for identifying anxiety and distress in cardiac patients with ICDs
Ebrahimi, A., Eriksen, J. B. R., Kølbæk, D. K., Pedersen, J. M., Christensen, E. V. J., Skovbakke, S. J., Skov, O., Pedersen, S. S., Azar, A. S., & Wiil, U. K. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-03315-x · Cited by 3 · see citing works
Transformers for Detection of Distressed Cardiac Patients with an ICD Based on Danish Text Messages
Andersen, J. D. W., Jensen, M. L., Wiil, U. K., Skovbakke, S. J., Skov, O., Pedersen, S. S., Peimankar, A., & Ebrahimi, A. (2023) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm58861.2023.10385964 · Cited by 2 · see citing works
A Real Time System to Analyze Patient's Health Condition using Second Layer Computing
Dinesh, E., Poovitha, K., Pranikaa, V., & Rosini, M. (2023) · International Conference on Computing Methodologies and Communication (ICCMC) · doi:10.1109/iccmc56507.2023.10084046 · Cited by 2 · see citing works
Calvagna, G. M., Patanè, S., Celona, A., Inserra, M. C., Vasquez, L., & Romeo, P. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.03.101 · Cited by 1 · see citing works
105 Inappropriate ICD Shocks in a Patient with Dilated Cardiomyopathy and Broca’s Aphasia
Georgi, C., Neuß, M., Möller, V., Seifert, M., & Butter, C. (2019) · Case Reports in Cardiology · doi:10.1155/2019/8302591 · Cited by 1 · see citing works
The Pivotal Role of Edge Computing With Machine Learning and Its Impact on Healthcare
Muthukumari, S. M., & Raj, G. D. P. E. (2020) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-7998-3591-2.ch014
The Pivotal Role of Edge Computing With Machine Learning and Its Impact on Healthcare
Muthukumari, S. M., & Raj, G. D. P. E. (2022) · IGI Global eBooks · doi:10.4018/978-1-6684-5700-9.ch033
- Authors
- Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R.
- Affiliations
- University of Ferrara (IT)
- Corresponding author
- Bertini, Matteo
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2016-01
- Volume
- 202
- Pages
- 368-377
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W1904692833
- Cited by
- 28
- References
- 68
- Citations by year
- 2025: 1 · 2023: 6 · 2022: 3 · 2021: 1 · 2020: 5 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 4
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Institutional Research Information System University of Ferrara (University of Ferrara) (submittedVersion)
- Funders
- Fondazione Anna Maria Sechi per il Cuore (FASC), Italy
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- remote monitoring, implantable cardioverter-defibrillator, inappropriate shocks, patient consent, heart failure, device reprogramming, physician acceptance, cost efficiency
- MeSH terms
- Humans, Monitoring, Physiologic, Defibrillators, Implantable, Remote Sensing Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review