The optimal technique for electrical cardioversion of atrial fibrillation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The optimal approach to electrical cardioversion of atrial fibrillation includes appropriate patient selection, anticoagulation, careful selection and monitoring of antiarrhythmic therapy, and proper electrical cardioversion technique. The optimal technique requires the use of metal electrodes, with one electrode of at least 8 cm in diameter placed in the anterior position, and the second of 12–13 cm diameter placed posteriorly just below the left scapulae, with generous amounts of the appropriate gel (such as Hewlett‐Packard Redux Paste) as the electrode‐skin interface and firm pressure to the paddle electrode with the patient in expiration. Thus the anterior‐posterior chest diameter is decreased and less air between the electrodes is assured. The initial shock strength should be 200 J. The shock is synchronized with the electrocardiographic QRS complex. This report reviews the justification for these recommendations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relation between echocardiographically determined left atrial size and atrial fibrillation.
Henry, W. L., Morganroth, J., Pearlman, A. S., Clark, C. E., Redwood, D. R., Itscoitz, S. B., & Epstein, S. E. (1976) · Circulation · doi:10.1161/01.cir.53.2.273 · Cited by 641
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
Metadata
- Authors
- Ewy, G. A.
- Venue
- Clinical Cardiology
- Publisher
- Wiley
- Published
- 1994-02
- Volume
- 17
- Issue
- 2
- Pages
- 79-84
- ISSN
- 0160-9289 (ISSN-L)
- 1932-8737
- OpenAlex
- W2022804283
- Cited by
- 66
- References
- 1
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.