Cited by 641Atrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsCardiac Valve Diseases and Treatments

Relation between echocardiographically determined left atrial size and atrial fibrillation.

Open access
Henry, W L, Morganroth, J, Pearlman, A S, Clark, C E, Redwood, D R, Itscoitz, S B, Epstein, S E·1976·Circulation

Abstract

In an attempt to define quantitatively the relation between left atrial size and atrial fibrillation, echocardiography was used to study 85 patients with isolated mitral valve disease, 50 patients with isolated aortic valve disease, and 130 patients with asymmetric septal hypertrophy. In all three groups of patients, atrial fibrillation was rare when left atrial dimension was below 44 mm (3 of 117 or 3%) but common when this dimension exceeded 40 mm (80 of 148 or 54%). In addition, when left atrial dimension exceeds 45 mm, cardioversion, while initially successful, is unlikely to produce sinus rhythm that can be maintained at least six months. These data suggest that left atrial size is an important factor in the development of atrial fibrillation and in determining the long term result of cardioversion. The pathophysiologic mechansim most consistent with this is that a chronic hemodynamic burden initially produces left atrial enlargement which in turn predisposes to atrial fibrillation. Only prospective studies will determine definitively whether these observations will be useful in decisions concerning prophylactic anticoagulation and elective cardioversion.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.53.2.273

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 18 · Cited by 641

Authors
Henry, W. L., Morganroth, J., Pearlman, A. S., Clark, C. E., Redwood, D. R., Itscoitz, S. B., & Epstein, S. E.
Affiliations
National Institutes of Health (US)
Venue
Circulation
Published
1976-02
Volume
53
Issue
2
Pages
273-279
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2052230379
Cited by
641
References
18
Citations by year
2026: 1 · 2025: 11 · 2024: 11 · 2023: 15 · 2022: 11 · 2021: 16 · 2020: 12 · 2019: 8 · 2018: 15 · 2017: 11 · 2016: 14 · 2015: 18 · 2014: 24 · 2013: 8 · 2012: 18
FWCI
6.02
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
Keywords
left atrial size, atrial fibrillation, left atrial enlargement, mitral valve disease, aortic valve disease, asymmetric septal hypertrophy, cardioversion, hemodynamic burden, anticoagulation
MeSH terms
Adolescent, Adult, Age Factors, Aged, Atrial Fibrillation, Cardiac Volume, Child, Echocardiography, Electric Countershock, Female, Heart Atria, Cardiomegaly, Heart Valve Diseases, Hemodynamics, Humans, Male, Middle Aged, Pulmonary Embolism

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review