The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Understanding implantable cardioverter defibrillator shocks and storms: Medical and psychosocial considerations for research and clinical care
Open accessAbstract
The experience of shock is the distinguishing feature for patients with implantable cardioverter defibrillators (ICDs) and is associated with diminished psychological functioning and quality of life. Multiple shocks and ICD storm are a relatively common event among patients with ICDs (10‐20%) and may present specific challenging medical and psychological management for the attending health care providers. This paper examines the medical and psychological aspects of ICD shocks and storms and describes a model of biopsychosocial management for patients following the experience of ICD storm. Successful management of patients post shock includes the use of antiarrhythmic medications and careful attention to the causality of the shocks via stored electrograms. The psychological management includes specific attention to debriefing post‐shock feelings and attributions, preventing avoidance behavior, and facilitating positive “return to life” actions. Preliminary research examining formal psychosocial treatment supports a cognitive behavioral strategy to reduce psychological distress and facilitate quality of life. Collectively, these data suggest that interdisciplinary management of patients with multiple ICD shocks or the experience of ICD storm is advised, and routine psychological consultation may be indicated for the patient post ICD storm to reduce the possibility of symptoms of post‐traumatic stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Metadata
- Authors
- Sears, S. F., & Conti, J. B.
- Venue
- Clinical Cardiology
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 26
- Issue
- 3
- Pages
- 107-111
- ISSN
- 0160-9289 (ISSN-L)
- 1932-8737
- OpenAlex
- W1983131787
- Cited by
- 167
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Understanding implantable cardioverter defibrillator shocks and storms: Medical and psychosocial considerations for research and clinical care. https://app.cochat.ai/papers/10.1002/clc.4960260303
- The paper
- Sears, S. F., & Conti, J. B. (2003). Understanding implantable cardioverter defibrillator shocks and storms: Medical and psychosocial considerations for research and clinical care. Clinical Cardiology. https://doi.org/10.1002/clc.4960260303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.