The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Characterization of Solid Counterfeit Drug Samples by Desorption Electrospray Ionization and Direct‐analysis‐in‐real‐time Coupled to Time‐of‐flight Mass Spectrometry
Abstract
Vacuum is not the limit: direct analysis in real time (DART), a new MS ionization method, allows probing of pharmaceuticals under atmospheric pressure, thus bypassing lengthy sample preparation steps and enhancing throughput. DART allows rapid screening of solid drugs at almost constant temperature which decreases errors in mass measurement and improves the identification of potentially harmful unknowns. This is important for identifying counterfeit drugs (fake hologram shown).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Self-citationAmbient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Van Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Metadata
- Authors
- Fernández, F. M., Cody, R. B., Green, M. D., Hampton, C. Y., McGready, R., Sengaloundeth, S., White, N. J., & Newton, P. N.
- Venue
- ChemMedChem
- Publisher
- Wiley
- Published
- 2006-06-30
- Volume
- 1
- Issue
- 7
- Pages
- 702-705
- ISSN
- 1860-7179 (ISSN-L)
- 1860-7187
- OpenAlex
- W2025228136
- Cited by
- 215
- References
- 1
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Solid Counterfeit Drug Samples by Desorption Electrospray Ionization and Direct‐analysis‐in‐real‐time Coupled to Time‐of‐flight Mass Spectrometry. https://app.cochat.ai/papers/10.1002/cmdc.200600041
- The paper
- Fernández, F. M., Cody, R. B., Green, M. D., Hampton, C. Y., McGready, R., Sengaloundeth, S., White, N. J., & Newton, P. N. (2006). Characterization of Solid Counterfeit Drug Samples by Desorption Electrospray Ionization and Direct‐analysis‐in‐real‐time Coupled to Time‐of‐flight Mass Spectrometry. ChemMedChem. https://doi.org/10.1002/cmdc.200600041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.