The DOI matches its Crossref record.
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Abstract
A low-temperature plasma (LTP) probe has been developed for ambient desorption ionization. An ac electric field is used to induce a dielectric barrier discharge through use of a specially designed electrode configuration. The low-temperature plasma is extracted from the probe where it interacts directly with the sample being analyzed, desorbing and ionizing surface molecules in the ambient environment. This allows experiments to be performed without damage to the sample or underlying substrate and, in the case of biological analysis on skin surfaces, without electrical shock or perceptible heating. Positive or negative ions are produced from a wide range of chemical compounds in the pure stateand as mixtures in the gaseous, solution, or condensed phases, using He, Ar, N2, or ambient air as the discharge gas. Limited fragmentation occurs, although it is greater in the cases of the molecular than the atomic discharge gases. The effectiveness of the LTP probe has been demonstrated by recording characteristic mass spectra and tandem mass spectra of samples containing hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and 2,4,6-trinitrotoluene (TNT) from poly(tetrafluoroethylene) (PTFE) surfaces where limits of detection are as low as 5 pg. Other performance characteristics, when using a commercial ion trap mass spectrometer, include 3-4 orders of magnitude linear dynamic range in favorable cases. Demonstration applications include direct analysis of cocaine from human skin, determination of active ingredients directly in drug tablets, and analysis of toxic and therapeutic compounds in complex biological samples. Ionization of chemicals directly from bulk aqueous solution has been demonstrated, where limits of detection are as low as 1 ppb. Large surface area sampling and control of fragmentation by a simple adjustment of the electrode configuration during operation are other demonstrated characteristics of the method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Miniature and Fieldable Mass Spectrometers: Recent Advances
Snyder, D. T., Pulliam, C. J., Ouyang, Z., & Cooks, R. G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03070 · Cited by 420
Self-citationAmbient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Ouyang, Z., & Cooks, R. G. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155229 · Cited by 323
Self-citationApplications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
Swiner, D. J., Jackson, S., Burris, B. J., & Badu-Tawiah, A. K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04901 · Cited by 73
Metadata
- Authors
- Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-11-05
- Volume
- 80
- Issue
- 23
- Pages
- 9097-9104
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2007116883
- Cited by
- 730
- References
- 0
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Temperature Plasma Probe for Ambient Desorption Ionization. https://app.cochat.ai/papers/10.1021/ac801641a
- The paper
- Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008). Low-Temperature Plasma Probe for Ambient Desorption Ionization. Analytical Chemistry. https://doi.org/10.1021/ac801641a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.