The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Influence of molecular parameters and increasing magnetic field strength on relaxivity of gadolinium‐ and manganese‐based T1 contrast agents
Open accessAbstract
Simulations were performed to understand the relative contributions of molecular parameters to longitudinal (r1) and transverse (r2) relaxivity as a function of applied field, and to obtain theoretical relaxivity maxima over a range of fields to appreciate what relaxivities can be achieved experimentally. The field‐dependent relaxivities of a panel of gadolinium and manganese complexes with different molecular parameters, water exchange rates, rotational correlation times, hydration state, etc. were measured to confirm that measured relaxivities were consistent with theory. The design tenets previously stressed for optimizing r1 at low fields (very slow rotational motion; chelate immobilized by protein binding; optimized water exchange rate) do not apply at higher fields. At 1.5T and higher fields, an intermediate rotational correlation time is desired (0.5–4 ns), while water exchange rate is not as critical to achieving a high r1. For targeted applications it is recommended to tether a multimer of metal chelates to a protein‐targeting group via a long flexible linker to decouple the slow motion of the protein from the water(s) bound to the metal ions. Per ion relaxivities of 80, 45, and 18 m M−1 s−1 at 1.5, 3 and 9.4 T, respectively, are feasible for Gd 3+ and Mn 2+ complexes. Copyright © 2009 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipari, G., & Szabo, A. (1982) · Journal of the American Chemical Society · doi:10.1021/ja00381a009 · Cited by 3,777
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Self-citationLanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Tuning the Magnetic Properties of Nanoparticles
Kolhatkar, A., Jamison, A., Litvinov, D., Willson, R., & Lee, T. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140815977 · Cited by 820
Jeon, M., Halbert, M. V., Stephen, Z. R., & Zhang, M. (2021) · Advanced Materials · doi:10.1002/adma.201906539 · Cited by 477
Size-Tunable, Ultrasmall NaGdF4 Nanoparticles: Insights into Their T1 MRI Contrast Enhancement
Johnson, N. J. J., Oakden, W., Stanisz, G. J., Scott Prosser, R., & van Veggel, F. C. J. M. (2011) · Chemistry of Materials · doi:10.1021/cm201297x · Cited by 414
Metadata
- Authors
- Caravan, P., Farrar, C. T., Frullano, L., & Uppal, R.
- Venue
- Contrast Media & Molecular Imaging
- Publisher
- Wiley
- Published
- 2009-01-28
- Volume
- 4
- Issue
- 2
- Pages
- 89-100
- ISSN
- 1555-4309 (ISSN-L)
- 1555-4317
- OpenAlex
- W1979927327
- Cited by
- 513
- References
- 1
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of molecular parameters and increasing magnetic field strength on relaxivity of gadolinium‐ and manganese‐based T1 contrast agents. https://app.cochat.ai/papers/10.1002/cmmi.267
- The paper
- Caravan, P., Farrar, C. T., Frullano, L., & Uppal, R. (2009). Influence of molecular parameters and increasing magnetic field strength on relaxivity of gadolinium‐ and manganese‐based T1 contrast agents. Contrast Media & Molecular Imaging. https://doi.org/10.1002/cmmi.267
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.