The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Influence of molecular parameters and increasing magnetic field strength on relaxivity of gadolinium‐ and manganese‐based T1 contrast agents
Open accessAbstract
Simulations were performed to understand the relative contributions of molecular parameters to longitudinal (r1) and transverse (r2) relaxivity as a function of applied field, and to obtain theoretical relaxivity maxima over a range of fields to appreciate what relaxivities can be achieved experimentally. The field‐dependent relaxivities of a panel of gadolinium and manganese complexes with different molecular parameters, water exchange rates, rotational correlation times, hydration state, etc. were measured to confirm that measured relaxivities were consistent with theory. The design tenets previously stressed for optimizing r1 at low fields (very slow rotational motion; chelate immobilized by protein binding; optimized water exchange rate) do not apply at higher fields. At 1.5T and higher fields, an intermediate rotational correlation time is desired (0.5–4 ns), while water exchange rate is not as critical to achieving a high r1. For targeted applications it is recommended to tether a multimer of metal chelates to a protein‐targeting group via a long flexible linker to decouple the slow motion of the protein from the water(s) bound to the metal ions. Per ion relaxivities of 80, 45, and 18 m M−1 s−1 at 1.5, 3 and 9.4 T, respectively, are feasible for Gd 3+ and Mn 2+ complexes. Copyright © 2009 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Self-citationLipari, G., & Szabo, A. (1982) · Journal of the American Chemical Society · doi:10.1021/ja00381a009 · Cited by 3,777
Relaxation Processes in a System of Two Spins
Solomon, I. (1955) · Physical Review · doi:10.1103/physrev.99.559 · Cited by 3,278
Model-free approach to the interpretation of nuclear magnetic resonance relaxation in macromolecules
Lipari, G. (1982) · Journal of the American Chemical Society · Cited by 2,525
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000184756.66360.d3 · Cited by 1,682
Reaction Rates by Nuclear Magnetic Resonance
McConnell, H. M. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744152 · Cited by 1,624
Strategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Self-citationProton Relaxation Times in Paramagnetic Solutions. Effects of Electron Spin Relaxation
Bloembergen, N., & Morgan, L. O. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731684 · Cited by 1,348
Swift, T. J., & Connick, R. E. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1701321 · Cited by 1,292
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Self-citationLanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Tuning the Magnetic Properties of Nanoparticles
Kolhatkar, A., Jamison, A., Litvinov, D., Willson, R., & Lee, T. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140815977 · Cited by 820
Jeon, M., Halbert, M. V., Stephen, Z. R., & Zhang, M. (2021) · Advanced Materials · doi:10.1002/adma.201906539 · Cited by 477
Size-Tunable, Ultrasmall NaGdF4 Nanoparticles: Insights into Their T1 MRI Contrast Enhancement
Johnson, N. J. J., Oakden, W., Stanisz, G. J., Scott Prosser, R., & van Veggel, F. C. J. M. (2011) · Chemistry of Materials · doi:10.1021/cm201297x · Cited by 414
A Manganese Alternative to Gadolinium for MRI Contrast
Gale, E. M., Atanasova, I. P., Blasi, F., Ay, I., & Caravan, P. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b10748 · Cited by 353
Self-citationGd(III)-Nanodiamond Conjugates for MRI Contrast Enhancement
Manus, L. M., Mastarone, D. J., Waters, E. A., Zhang, X.-Q., Schultz-Sikma, E. A., MacRenaris, K. W., Ho, D., & Meade, T. J. (2010) · Nano Letters · doi:10.1021/nl903264h · Cited by 312
Radioactive Transition Metals for Imaging and Therapy
Boros, E., & Packard, A. B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00281 · Cited by 299
Molecular Magnetic Resonance Imaging with Gd(III)-Based Contrast Agents: Challenges and Key Advances
Li, H., & Meade, T. J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09149 · Cited by 288
Li, B., Gu, Z., Kurniawan, N., Chen, W., & Xu, Z. P. (2017) · Advanced Materials · doi:10.1002/adma.201700373 · Cited by 258
Li, Y., Zhang, P., Tang, W., McHugh, K. J., Kershaw, S. V., Jiao, M., Huang, X., Kalytchuk, S., Perkinson, C. F., Yue, S., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c01153 · Cited by 98
Bartelle, B. B., Barandov, A., & Jasanoff, A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.4050-15.2016 · Cited by 45
Litti, L., Rivato, N., Fracasso, G., Bontempi, P., Nicolato, E., Marzola, P., Venzo, A., Colombatti, M., Gobbo, M., & Meneghetti, M. (2018) · Nanoscale · doi:10.1039/c7nr07398d · Cited by 33
Metadata
- Authors
- Caravan, P., Farrar, C. T., Frullano, L., & Uppal, R.
- Venue
- Contrast Media & Molecular Imaging
- Publisher
- Wiley
- Published
- 2009-01-28
- Volume
- 4
- Issue
- 2
- Pages
- 89-100
- ISSN
- 1555-4309 (ISSN-L)
- 1555-4317
- OpenAlex
- W1979927327
- Cited by
- 513
- References
- 30
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.