Magnets of the Halbach layout are interesting for the use in mobile NMR/MRI devices. Therefore, the ideal Halbach magnet was iterated using identical bar magnets, which are positioned and oriented based on analytical equations. These configurations were simulated with two‐dimensional finite‐element methods. Performance factors were defined to relate field strength with homogeneity and mass. A geometry of 16 magnets provided a good compromise between performance and special requirements for the desired use to store hyperpolarized xenon. The construction of such a magnet required the design of dedicated support frames and procedures to mount them. The field strength and homogeneity in the finished magnet were measured by a Hall probe and agreed well with the simulations. The calculation and construction are described in detail and together with the tabled field values for n magnets with n ≤ 80 may prove helpful for building similar devices, which were named NMR Mandhalas (Magnet Arrangements for Novel Discrete Halbach Layout). © 2004 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 23B: 16–25, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Design of permanent multipole magnets with oriented rare earth cobalt material
Halbach, K. (1980) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(80)90094-4 · Cited by 1,532
Electromagnetic Analysis and Design in Magnetic Resonance Imaging
Jin, J. (2018) · Routledge eBooks · doi:10.1201/9780203758731 · Cited by 502
Halbach permanent magnet machines andapplications: a review
Zhu, Z. Q., & Howe, D. (2001) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20010479 · Cited by 383
Permanent magnet materials and their application
(1997) · Materials Characterization · doi:10.1016/s1044-5803(97)80022-8 · Cited by 267
Strong Rare Earth Cobalt Quadrupoles
Halbach, K. (1979) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1979.4330638 · Cited by 119
Miniature permanent magnet for table‐top NMR
Moresi, G., & Magin, R. L. (2003) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.10082 · Cited by 111
Multi-Tesla permanent magnet field sources
Leupold, H. A., Tilak, A. S., & Potenziani, E., II (1993) · Journal of Applied Physics · doi:10.1063/1.352463 · Cited by 20
Cited by
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
Low-field permanent magnets for industrial process and quality control
Mitchell, J., Gladden, L. F., Chandrasekera, T. C., & Fordham, E. J. (2014) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.09.001 · Cited by 300
Wald, L. L., McDaniel, P. C., Witzel, T., Stockmann, J. P., & Cooley, C. Z. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26942 · Cited by 272
Kang, J. H., Driscoll, H., Super, M., & Ingber, D. E. (2016) · Applied Physics Letters · doi:10.1063/1.4952612 · Cited by 21
Metadata
- Authors
- Raich, H., & Blümler, P.
- Venue
- Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering
- Publisher
- Wiley
- Published
- 2004-10
- Volume
- 23B
- Issue
- 1
- Pages
- 16-25
- ISSN
- 1552-5031 (ISSN-L)
- 1552-504X
- OpenAlex
- W2105527551
- Cited by
- 296
- References
- 8
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.