The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Application of a Halbach magnetic array for long-range cell and particle separations in biological samples
Abstract
Here, we describe a versatile application of a planar Halbach permanent magnet array for an efficient long-range magnetic separation of living cells and microparticles over distances up to 30 mm. A Halbach array was constructed from rectangular bar magnets using 3D-printed holders and compared to a conventional alternating array of identical magnets. We theoretically predicted the superiority of the Halbach array for a long-range magnetic separation and then experimentally validated that the Halbach configuration outperforms the alternating array for isolating magnetic microparticles or microparticle-bound bacterial cells at longer distances. Magnetophoretic velocities (ymag) of magnetic particles (7.9 μm diameter) induced by the Halbach array in a microfluidic device were significantly higher and extended over a larger area than those induced by the alternating magnet array (ymag = 178 versus 0 μm/s at 10 mm, respectively). When applied to 50 ml tubes (∼30 mm diameter), the Halbach array removed >95% of Staphylococcus aureus bacterial cells bound with 1 μm magnetic particles compared to ∼70% removed using the alternating array. In addition, the Halbach array enabled manipulation of 1 μm magnetic beads in a deep 96-well plate for ELISA applications, which was not possible with the conventional magnet arrays. Our analysis demonstrates the utility of the Halbach array for the future design of devices for high-throughput magnetic separations of cells, molecules, and toxins.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Halbach arrays generate the strongest magnetic force over a large distance.
“In the literature, so-called Halbach arrays have proven to be particularly suitable for particle steering, as they generate the strongest magnetic force over a large distance [7][8][9].”
From Experimental and Simulative Analysis of Magnetic Nanoparticle Accumulation Using Various Halbach Arrays (2024) · cites this paper as [12]
Citations
Cites
Design of permanent multipole magnets with oriented rare earth cobalt material
Halbach, K. (1980) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(80)90094-4 · Cited by 1,532
Flagged first, then by citations
Research works printed but not linked: 23
- 2003, J. Phys. D: Appl. Phys., 36, R167, 10.1088/0022-3727/36/13/201 · DOI
- 1965, The Theory of Electric and Magnetic Susceptibilities
- 2004, Appl. Phys. Lett., 85, 5093, 10.1063/1.1823015 · DOI
- 2007, Small, 3, 1784, 10.1002/smll.200700334 · DOI
- 2006, Biomed. Microdevices, 8, 299, 10.1007/s10544-006-0033-0 · DOI
- 2004, J. Appl. Phys., 96, 5797, 10.1063/1.1803628 · DOI
- 2003, Appl. Phys. Lett., 83, 2396, 10.1063/1.1613038 · DOI
- 2004, Microfluid. Nanofluid., 1, 22, 10.1007/s10404-004-0010-y · DOI
- 2014, Nat. Med., 20, 1211, 10.1038/nm.3640 · DOI
- 2012, J. Magn. Magn. Mater., 324, 742, 10.1016/j.jmmm.2011.09.008 · DOI
- 2008, International Conference on Electrical Machines and Systems (ICEMS 2008), 368
- 2004, Concepts Magn. Reson., 23B, 16, 10.1002/cmr.b.20018 · DOI
- 2001, IEE Proc.: Electric Power Applications, 148, 299, 10.1049/ip-epa:20010479 · DOI
- 2013, IEEE Trans. Magn., 49, 3449, 10.1109/TMAG.2013.2244577 · DOI
- 2011, J. Magn. Magn. Mater., 323, 1384, 10.1016/j.jmmm.2010.11.051 · DOI
- Finite Element Method Magnetics (FEMM)
- 2015, Small, 11, 5657, 10.1002/smll.201501820 · DOI
- 2005, Lab Chip, 5, 657, 10.1039/b502225h · DOI
- 2007, Lab Chip, 7, 1294, 10.1039/b705045c · DOI
- 2006, Exp. Fluids, 41, 161, 10.1007/s00348-006-0154-5 · DOI
- 2006, Science, 314, 964, 10.1126/science.1131475 · DOI
- 2015, Front. Microbiol., 5, 770, 10.3389/fmicb.2014.00770 · DOI
- 2012, Anal. Chem., 84, 9470, 10.1021/ac302301w · DOI
Cited by
Sorted by citations
3D-printed microfluidic manipulation device integrated with magnetic array
Wu, J., Cui, Y., Xuan, S., & Gong, X. (2018) · Microfluidics and Nanofluidics · doi:10.1007/s10404-018-2123-8 · Cited by 20
Thalmayer, A. S., Götz, K., Lübke, M., & Fischer, G. (2024) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2024-2159
Metadata
- Authors
- Kang, J. H., Driscoll, H., Super, M., & Ingber, D. E.
- Affiliations
- Wyss Institute for Biologically Inspired Engineering (US)
- Boston Children's Hospital (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2016-05-23
- Volume
- 108
- Issue
- 21
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2397405457
- Cited by
- 21
- References
- 1
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 1
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
- Funders
- Wyss Institute for Biologically Inspired Engineering at Harvard University
- Defense Advanced Research Projects Agency (HR0011-13-C-0025, N66001-11-1-4180)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Keywords
- Halbach array, permanent magnet array, magnetophoresis, magnetic microparticles, Staphylococcus aureus, microfluidics, 3D-printed holder
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review