The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
The distribution of rods and cones in the retina of the cat (Felis domesticus)
Abstract
The distribution of rods and cones in the cat retina was studied by light microscopy. The rods and cones were counted from the area centralis to the temporal periphery in photomicrographs of transverse sections through the inner segments. A 16% correction for the effect of tissue shrinkage was applied to the densities obtained in fixed‐dehydrated tissue, by comparing these counts with those obtained from similar retinal areas in fresh tissue. The cone distribution was characterized by a steep increase in cone density centrally, which was elongated in the nasotemporal axis, and coincided approximately with the central increase in ganglion cell density (Stone, '65). Cone density in the area centralis peaked at 26,000–27,000/mm 2, and fell to a plateau of 4000/mm 2 in the periphery and to less than 3000/mm 2 near the ora serrata. The density of rods was greater than the density of cones in all regions. The rods reached a maximum density of 460,000/mm 2 at an eccentricity of 10–15°, in a region which completely surrounded the central cone elevation. Centrally, the rod distribution was characterized by a sharp fall in density, reaching a low of 275,000/mm 2 at the point of peak cone density. Peripherally, there was a plateau of high rod density at above 400,000/mm 2, out to about 30° temporal eccentricity. Beyond this plateau, rod density steadily fell, and reached a low of 250,000/mm 2 near the ora serrata. The rod/cone ratio reached a low value of 10.5–11.0 in the central region of maximum cone density. It then rose steeply to reach a plateau of about 65 in the periphery, while near the ora serrata there were 100 rods for each cone. The rods were arranged in well defined rows, and each rod was surrounded by six other rods. The cones were interspersed throughout the rod mosaic and were less regularly arranged than the rods. In fresh tissue, rod outer segment diameters ranged from 1.0 μ to 1.6 μ. rod diameters were smallest in the region of maximum rod density and increased, along with the decrease in rod density, both in the periphery and in the area centralis. Two thirds of the central decrease in rod density from the pericentral peak could not be accounted for by the increase in the percentage of space occupied by cones, and was consistent with a central increase in rod diameter. Receptor‐ganglion cell convergence was estimated by comparing receptor densities with the ganglion cell densities of Stone ('65). Cone‐ganglion cell convergence reached a minimum in the area centralis at the cone density peak, probably indicating the retinal region in which photopic acuity is at an optimum. Minimum rod‐ganglion cell convergence, as estimated from the rod/large ganglion cell ratio, reached a minimum at about 7.5° central to the peak of rod density, and at about the same eccentricity as the human scotopic acuity optimum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
Optical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595
Topography of the Layer of Rods and Cones in the Human Retina
(1937) · Journal of the American Medical Association · doi:10.1001/jama.1937.02780030070033 · Cited by 817
Bishop, P. O., Kozak, W., & Vakkur, G. J. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006990 · Cited by 432
THE RENEWAL OF ROD AND CONE OUTER SEGMENTS IN THE RHESUS MONKEY
Young, R. W. (1971) · The Journal of Cell Biology · doi:10.1083/jcb.49.2.303 · Cited by 375
A quantitative analysis of the distribution of ganglion cells in the cat's retina
Stone, J. (1965) · The Journal of Comparative Neurology · doi:10.1002/cne.901240305 · Cited by 344
Visual Sensory Units and the Minimal Angle of Resolution
Weymouth, F. W. (1958) · American Journal of Ophthalmology · doi:10.1016/0002-9394(58)90042-4 · Cited by 279
Henderson, T. (1943) · British Journal of Ophthalmology · doi:10.1136/bjo.27.3.138 · Cited by 276
Rolls, E. T., & Cowey, A. (1970) · Experimental Brain Research · doi:10.1007/bf00235053 · Cited by 274
Receptive fields of ganglion cells in the cat's retina
Wiesel, T. N. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006557 · Cited by 208
Quantitative aspects of sensitivity and summation in the cat retina
Cleland, B. G., & Enroth‐Cugell, C. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008591 · Cited by 154
Pirenne, M. H. (1967) · Medical Entomology and Zoology · Cited by 133
Morris, V. B. (1970) · The Journal of Comparative Neurology · doi:10.1002/cne.901400308 · Cited by 115
Specialized Receptive Fields of the Cat's Retina
Stone, J., & Fabian, M. (1966) · Science · doi:10.1126/science.152.3726.1277 · Cited by 88
Visual Discrimination in the Cat: IV. The Visual Acuity of the Cat in Relation to Stimulus Distance
Smith, K. U. (1936) · The Pedagogical Seminary and Journal of Genetic Psychology · doi:10.1080/08856559.1936.10533772 · Cited by 53
Visual Acuity of the Cat estimated from Evoked Cerebral Potentials
Berkley, M. A., & WATKINS, D. W. (1971) · Nature New Biology · doi:10.1038/newbio234091a0 · Cited by 28
Cited by
Topography of ganglion cells in human retina
Curcio, C. A., & Allen, K. A. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.903000103 · Cited by 1,844
Chapter 9 Visual adaptation and retinal gain controls
Shapley, R., & Enroth-Cugell, C. (1984) · Progress in Retinal Research · doi:10.1016/0278-4327(84)90011-7 · Cited by 885
Nuclear Architecture of Rod Photoreceptor Cells Adapts to Vision in Mammalian Evolution
Solovei, I., Kreysing, M., Lanctôt, C., Kösem, S., Peichl, L., Cremer, T., Guck, J., & Joffe, B. (2009) · Cell · doi:10.1016/j.cell.2009.01.052 · Cited by 790
Immunocytochemical analysis of the mouse retina
Haverkamp, S., & W�ssle, H. (2000) · The Journal of Comparative Neurology · doi:10.1002/1096-9861(20000814)424:1<1::aid-cne1>3.0.co;2-v · Cited by 710
Hughes, A. (1977) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-66468-7_11 · Cited by 588
Metadata
- Authors
- Steinberg, R. H., Reid, M., & Lacy, P. L.
- Venue
- Journal of Comparative Neurology
- Publisher
- Wiley
- Published
- 1973-03-15
- Volume
- 148
- Issue
- 2
- Pages
- 229-248
- ISSN
- 0021-9967 (ISSN-L)
- 1096-9861
- OpenAlex
- W2038961805
- Cited by
- 277
- References
- 16
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.