The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A collagen‐based nerve guide conduit for peripheral nerve repair: An electrophysiological study of nerve regeneration in rodents and nonhuman primates
Abstract
When a peripheral nerve is severed and left untreated, the most likely result is the formation of an endbulb neuroma; this tangled mass of disorganized nerve fibers blocks functional recovery following nerve injury. Although there are several different approaches for promoting nerve repair, which have been greatly refined over recent years, the clinical results of peripheral nerve repair remain very disappointing. In this paper we compare the results of a collagen nerve guide conduit to the more standard clinical procedure of nerve autografting to promote repair of transected peripheral nerves in rats and nonhuman primates. In rats, we tested recovery from sciatic nerve transection and repair by (1) direct microsurgical suture, (2) 4 mm autograft, or (3) entubulation repair with collagen‐based nerve guide conduits. Evoked muscle action potentials (MAP), were recorded from the gastrocnemius muscle at 4 and 12 weeks following sciatic nerve transection. At 4 weeks the repair group of direct suture demonstrated a significantly greater MAP, compared to the other surgical repair groups. However, at 12 weeks all four surgical repair groups displayed similar levels of recovery of the motor response. In six adult male Macaca fascicularis monkeys the median nerve was transected 2 cm above the wrist and repaired by either a 4 mm nerve autograft or a collagen‐based nerve guide conduit leaving a 4 mm gap between nerve ends. Serial studies of motor and sensory fibers were performed by recording the evoked MAP from the abductor pollicis brevis muscle (APB) and the sensory action potential (SAP) evoked by stimulation of digital nerves (digit II), respectively, up to 760 days following surgery. Evoked muscle responses returned to normal baseline levels in all cases. Statistical analysis of the motor responses, as judged by the slope of the recovery curves, indicated a significantly more rapid rate of recovery for the nerve guide repair group. The final level of recovery of the MAP amplitudes was not significantly different between the groups. In contrast, the SAP amplitude only recovered to the low normal range and there were no statistically significant differences between the two groups in terms of sensory recovery rates. The rodent and primate studies suggest that in terms of recovery of physiological responses from target muscle and sensory nerves, entubulation repair of peripheral nerves with a collagen‐based nerve guide conduit over a short nerve gap (4 mm) is as effective as a standard nerve autograft. Furthermore, preliminary results show that entubulation repair with this material can support axon regeneration and maturation over a nerve gap distance of at least 15 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of collagenous matrices in the adhesion and growth of cells.
Kleinman, H. K., Klebe, R. J., & Martin, G. R. (1981) · The Journal of cell biology · doi:10.1083/jcb.88.3.473 · Cited by 1,361
Surgery of the peripheral nerve
Harrison, D. H. (1989) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(89)90093-3 · Cited by 807
Sunderland, S., & SMITH, J. W. (1969) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-196912000-00013 · Cited by 752
Nerve regeneration in silicone chambers: Influence of gap length and of distal stump components
Lundborg, G., Dahlin, L. B., Danielsen, N., Gelberman, R. H., Longo, F. M., Powell, H. C., & Varon, S. (1982) · Experimental Neurology · doi:10.1016/0014-4886(82)90215-1 · Cited by 618
Madison, R., da Silva, C. F., Dikkes, P., Chiu, T.-H., & Sidman, R. L. (1985) · Experimental Neurology · doi:10.1016/0014-4886(85)90087-1 · Cited by 298
Self-citationIn Vivo Regeneration of Cut Nerves Encased in Silicone Tubes: Growth across a Six-millimeter Gap
LUNDBORG, G., GELBERMAN, R. H., LONGO, F. M., POWELL, H. C., & VARON, S. (1982) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-198207000-00004 · Cited by 243
Granulocyte collagenase: selective digestion of type I relative to type III collagen.
Horwitz, A. L., Hance, A. J., & Crystal, R. G. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.3.897 · Cited by 204
Regeneration of peripheral nerve through a polyglactin tube
Molander, H., Olsson, Y., Engkvist, O., Bowald, S., & Eriksson, I. (1982) · Muscle & Nerve · doi:10.1002/mus.880050110 · Cited by 186
Alteration of Neuroma Formation by Manipulation of Its Microenvironment
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1985) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198509000-00001 · Cited by 177
Piezoelectric guidance channels enhance regeneration in the mouse sciatic nerve after axotomy
Aebischer, P., Valentini, R. F., Dario, P., Domenici, C., & Galletti, P. M. (1987) · Brain Research · doi:10.1016/0006-8993(87)91570-8 · Cited by 167
Buchthal, F., & Kühl, V. (1979) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.42.5.436 · Cited by 139
Alteration of Neuroma Formation by Manipulation of Its Microenvironment
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1985) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198509000-00002 · Cited by 136
Aebischer, P., Guénard, V., Winn, S. R., Valentini, R. F., & Galletti, P. M. (1988) · Brain Research · doi:10.1016/0006-8993(88)90817-7 · Cited by 118
Lundborg, G., Dahlin, L. B., Danielsen, N., Hansson, H. A., & Larsson, K. (1981) · Journal of Neuroscience Research · doi:10.1002/jnr.490060302 · Cited by 111
Aebischer, P., Guénard, V., & Brace, S. (1989) · Journal of Neuroscience · doi:10.1523/jneurosci.09-10-03590.1989 · Cited by 97
Nerve regeneration through biodegradable polyester tubes
Henry, E., Chiu, T.-H., Nyilas, E., Brushart, T. M. E., Dikkes, P., & Sidman, R. L. (1985) · Experimental Neurology · doi:10.1016/0014-4886(85)90162-1 · Cited by 91
da Silva, C. F., Madison, R. D., Dikkes, P., Chiu, T.-H., & Sidman, R. L. (1985) · Brain Research · doi:10.1016/0006-8993(85)91130-8 · Cited by 83
Self-citationAxons regenerated through silicone tube splices
Fields, R. D., & Ellisman, M. H. (1986) · Experimental Neurology · doi:10.1016/0014-4886(86)90124-x · Cited by 77
Krarup, C., Loeb, G. E., & Pezeshkpour, G. H. (1988) · Muscle & Nerve · doi:10.1002/mus.880110906 · Cited by 67
Self-citationAxons regenerated through silicone tube splices
Fields, R. D., & Ellisman, M. H. (1986) · Experimental Neurology · doi:10.1016/0014-4886(86)90125-1 · Cited by 48
Ashur, H., Vilner, Y., Finsterbush, A., ROUSSO, M., Weinberg, H., & Devor, M. G. (1987) · Experimental Neurology · doi:10.1016/0014-4886(87)90096-3 · Cited by 48
Fascicular Tubulization: A Cellular Approach to Peripheral Nerve Repair
Rosen, J. M., Hentz, V. R., & Kaplan, E. N. (1983) · Annals of Plastic Surgery · doi:10.1097/00000637-198311000-00007 · Cited by 46
Fascicular nerve graft using an empty perineurial tube: An experimental study in the rabbit
Restrepo, Y., Merle, M., Michon, J., et al. (1983) · Microsurgery · doi:10.1002/micr.1920040207 · Cited by 35
Krarup, C., Upton, J. M., & Creager, M. A. (1990) · Muscle & Nerve · doi:10.1002/mus.880130404 · Cited by 33
Self-citationBiodegradable Cuff An Adjunct to Peripheral Nerve Repair: A Study in Dogs
Reid, R. L., Cutright, D. E., & Garrison, J. S. (1978) · HAND · doi:10.1016/s0072-968x(78)80047-3 · Cited by 27
Cited by
Collagen-Based Biomaterials for Tissue Engineering Applications
Parenteau-Bareil, R., Gauvin, R., & Berthod, F. (2010) · Materials · doi:10.3390/ma3031863 · Cited by 1,256
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,071
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Lundborg, G. (2000) · The Journal of Hand Surgery · doi:10.1053/jhsu.2000.4165 · Cited by 656
FTIR analysis of natural and synthetic collagen
Riaz, T., Zeeshan, R., Zarif, F., Ilyas, K., Muhammad, N., Safi, S. Z., Rahim, A., Rizvi, S. A. A., & Rehman, I. U. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1426595 · Cited by 628
Metadata
- Authors
- Archibald, S. J., Krarup, C., Shefner, J., Li, S., & Madison, R. D.
- Venue
- Journal of Comparative Neurology
- Publisher
- Wiley
- Published
- 1991-04-22
- Volume
- 306
- Issue
- 4
- Pages
- 685-696
- ISSN
- 0021-9967 (ISSN-L)
- 1096-9861
- OpenAlex
- W2105454620
- Cited by
- 374
- References
- 25
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.