The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method
Abstract
There is an important interaction between the pumping performance of the ventricle, arterial haemodynamics and coronary blood flow. While previous non‐linear 1D models have focused only on one of these components, the model presented in this study includes coronary and systemic arterial circulations, as well as ventricular pressure and an aortic valve that opens and closes ‘independently’ and based on local haemodynamics. The systemic circulation is modelled as a branching network of elastic tapering vessels. The terminal element applied at the extremities of the network is a single tapering vessel which is shown to adequately represent the input characteristics of the downstream vasculature. The coronary model consists of left and right coronary arteries which both branch into two ‘equivalent’ vessels that account for the lumped characteristics of subendocardial and subepicardial flows. As contracting heart muscle causes significant compression of the subendocardial vessels, a time‐varying external pressure proportional to ventricular pressure is applied to the distal part of the equivalent subendocardial vessel. The aortic valve is modelled using a variable reflection coefficient with respect to backward‐running aortic waves, and a variable transmission coefficient with respect to forward‐running ventricular waves. A realistic ventricular pressure is the input to the system; however, an afterload‐corrected ventricular pressure is calculated and results in pressure gradients between the ventricle and aorta that are similar to those observed in vivo. The 1D equations of fluid flow are solved using the locally conservative Galerkin method, which provides explicit element‐wise conservation, and can naturally incorporate vessel branching. Each component of the model is verified using a number of tests to ensure accuracy and reveal the underlying processes that give rise to complex pressure and flow waveforms. The complete model is then implemented, and simulations are performed with input parameters representing ‘at rest’ and exercise states for a normal adult. The resulting waveforms contain all of the important features seen in vivo, and standard measures of haemodynamic state are found to be normal. In addition, one or several characteristics of some common diseases are imposed on the model and are found to produce haemodynamic changes that agree with experimental observations in the published literature. Using a patient‐specific carotid bifurcation geometry, 1D velocity waveforms are also compared with waveforms obtained from a three‐dimensional model. The 1D and 3D results show good agreement. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Womersley, J. R. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005276 · Cited by 1,835
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684
Anliker, M., Rockwell, R. L., & Ogden, E. (1971) · Zeitschrift für angewandte Mathematik und Physik ZAMP · doi:10.1007/bf01591407 · Cited by 202
Cited by
Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.041 · Cited by 441
Metadata
- Authors
- Mynard, J. P., & Nithiarasu, P.
- Venue
- Communications in Numerical Methods in Engineering
- Publisher
- Wiley
- Published
- 2008-03-11
- Volume
- 24
- Issue
- 5
- Pages
- 367-417
- ISSN
- 1069-8299 (ISSN-L)
- 1099-0887
- OpenAlex
- W2140552189
- Cited by
- 230
- References
- 3
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method. https://app.cochat.ai/papers/10.1002/cnm.1117
- The paper
- Mynard, J. P., & Nithiarasu, P. (2008). A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method. Communications in Numerical Methods in Engineering. https://doi.org/10.1002/cnm.1117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.